Memory Maps and Registers

5.5.17 PLD Watchdog Control Register

The MVME2500 provides a watchdog control register.

Table 5-20 PLD Watchdog Control Register

REG

PLD Watch Dog Timer Load - 0xFFC80604

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bit

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field

Watchdog_EN

RSVD

RSVD

RSVD

RSVD

RSVD

RSVD

RSVD

RSVD

RSVD

RSVD

RSVD

RSVD

RSVD

RSVD

RSVD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPER

R/W

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RESET

0000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field Description

EN

Enable. If cleared, the watchdog timer is disabled. If set, the watchdog timer is

 

enabled.

5.5.18 PLD Watchdog Timer Count Register

The MVME2500 provides a watchdog timer count register.

Table 5-21 PLD Watchdog Timer Count Register

REG

PLD Watchdog Timer Count - 0xffc80606

 

 

Bit

15:0

 

 

Field

Count

 

 

OPER

R/W

 

 

RESET

0xEA60 (60secs)

 

 

MVME2500 Installation and Use (6806800L01H)

97

Page 97
Image 97
Emerson MVME2500 manual PLD Watchdog Control Register, PLD Watchdog Timer Count Register