Emerson MVME2500 7.4 I2C Bus Device Addressing, Ethernet PHY Address, 3 I2C Bus Device Addressing

Models: MVME2500

1 146
Download 146 pages 3.01 Kb
Page 118
Image 118

Programming Model

7.4I2C Bus Device Addressing

The following table contains the I2C devices used for the MVME2500 and its assigned device address.

Table 7-3 I2C Bus Device Addressing

I2C Bus Address

Device Function

Size

Notes

 

 

 

 

0x50

SPD

256 x 8

 

 

 

 

 

0x4C

ADT 7461 Temperature Sensor

N/A

 

 

 

 

 

0x68

DS 1375 real-time clock

N/A

 

 

 

 

 

0x54

VPD

8192 x 8

1

 

 

 

 

0x52

User configuration

65536 x 8

1

 

 

 

 

0x53

User configuration

65536 x 8

1

 

 

 

 

0x55

RTM EEPROM

8192 X 8

1, 2

 

 

 

 

0x56

XMC EEPROM

N/A

3

 

 

 

 

1.This is a dual address serial EEPROM.

2.The RTM Bus address can be manually changed through the S1 Switch on RTM. The default switch configuration will set the address to 0x55. Make sure that the address is unique to the RTM Bus address when setting the switch.

3.The address of the XMC EEPROM is configured through Geographic Address resistor on board.

7.5Ethernet PHY Address

The assigned Ethernet PHY on the MII management bus is shown in the following table.

Table 7-4 PHY Types and MII Management Bus Address

 

 

 

PHY MIIM

Ethernet Port

Function / Location

PHY Types

Address

 

 

 

 

TSEC1

Gigabit Ethernet port routed to front panel

BCM54616

1

 

 

 

 

118

MVME2500 Installation and Use (6806800L01H)

Page 118
Image 118
Emerson MVME2500 manual 7.4 I2C Bus Device Addressing, Ethernet PHY Address, 3 I2C Bus Device Addressing, Programming Model