Emerson MVME2500 manual 1 Environmental Requirements, Hardware Preparation and Installation

Models: MVME2500

1 146
Download 146 pages 3.01 Kb
Page 27
Image 27

Hardware Preparation and Installation

2.3.1Environmental Requirements

Operating temperatures refer to the temperature of the air circulating around the board and not to the component temperature.

Table 2-1 Environmental Requirements

Characteristics

Commercial Versions

Extended Temperature Versions

 

 

 

Applicable Variants

MVME2500-0163

MVME2500ET-0173

 

MVME2500-0161

MVME2500ET-0171

 

MVME2500-0173

 

 

MVME2500-0171

 

 

 

 

Cooling Method

Forced Air 7 CFM1

Forced Air 7 CFM1

Operating

0°C to +55°C

-40°C to +71°C

Temperature

 

 

 

 

 

Storage

-40°C to +85°C

-50°C to +100°C

 

 

 

Vibration Sine

2 G, 5 to 2000 Hz

10 G, 15 to 2000 Hz

(10min/axis)

 

 

 

 

 

Vibration Random

0.01g2/Hz, 15 to 2000 Hz

0.04g2/Hz, 15 to 2000 Hz (8

(1hr/axis)

 

GRMS)2

Shock

20g/11 mS

30g/11 mS

 

 

 

Humidity

to 95% RH (non-condensing)

to 100% RH (non-condensing)

 

 

 

1. ft3/min

 

 

2. Flat 15-1000Hz, -6db/octave 1000Hz - 2000Hz [MIL-STD 810F Figure 514.5C-17]