ModemModule Developer’s Guide
| +FDCC | Fax Capability Parameters | 
 | |||
| Command syntax: | +FDCC=VR,RB,WD,LN,DF,EC,BF,ST | ||||
| Response syntax: | VR,BR,WD,LN,DF,EC,BF,ST | 
 | |||
| 
 | 
 | Valid values: | 
 | 
 | |
| 
 | 
 | VR: | Vertical resolution | 
 | |
| 
 | 
 | 
 | 0: Normal, 98 lpi | 
 | |
| 
 | 
 | 
 | 1: Fine, 196 lpi | 
 | |
| 
 | 
 | BR: | Bit rate | 
 | 
 | 
| 
 | 
 | 
 | 0: 2400 bits/s V.27ter | 
 | |
| 
 | 
 | 
 | 1: 4800 bits/s V.27ter | 
 | |
| 
 | 
 | 
 | 2: 7200 bits/s V.29 or V.17 | ||
| 
 | 
 | 
 | 3: 9600 bits/s V.29 or V.17 | ||
| 
 | 
 | 
 | 4: 12000 bits/s V.33 or V.17 | ||
| 
 | 
 | 
 | 5: 14400 bits/s V.33 or V.17 | ||
| 
 | 
 | WD: | Page width | 
 | |
| 
 | 
 | 
 | 0: 1728 pixels in 215 mm | ||
| 
 | 
 | LN: | Page length | 
 | |
| 
 | 
 | 
 | 0: A4, 297 mm | 
 | |
| 
 | 
 | 
 | 2: Unlimited length | 
 | |
| 
 | 
 | DF: | Data compression format | ||
| 
 | 
 | 
 | 0:  | ||
| 
 | 
 | EC: | Error correction | 
 | |
| 
 | 
 | 
 | 0: Disable ECM | 
 | |
| 
 | 
 | BF: | Binary file transfer | 
 | |
| 
 | 
 | 
 | 0: Disable BFT | 
 | |
| 
 | 
 | ST: | Scan time/line | 
 | |
| 
 | 
 | 
 | 
 | VR = normal | VR = Fine | 
| 
 | 
 | 
 | 0: | 0 ms | 0 ms | 
| 
 | 
 | 
 | 1: | 5 ms | 5 ms | 
| 
 | 
 | 
 | 2: | 10 ms | 5 ms | 
| 
 | 
 | 
 | 3: | 10 ms | 10 ms | 
| 
 | 
 | 
 | 4: | 20 ms | 10 ms | 
| 
 | 
 | 
 | 5: | 20 ms | 20 ms | 
| 
 | 
 | 
 | 6: | 40 ms | 20 ms | 
| 
 | 
 | 
 | 7: | 40 ms | 40 ms | 
| +FDCS | Current Session Results | ||
| Command syntax: | +FDCS? | ||
| Response syntax: | +FDCS=VR,BR,WD,LN,DF,EC,BF,ST | ||
| 
 | 
 | Valid values: | |
| 
 | 
 | VR: | Vertical resolution | 
| 
 | 
 | 
 | 0: Normal, 98 lpi | 
| 
 | 
 | 
 | 1: Fine, 196 lpi | 
| 
 | 
 | BR: | Bit rate | 
| 
 | 
 | 
 | 0: 2400 bits/s V.27ter | 
| 
 | 
 | 
 | 1: 4800 bits/s V.27ter | 
| 
 | 
 | 
 | 2: 7200 bits/s V.29 or V.17 | 
| 
 | 
 | 
 | 3: 9600 bits/s V.29 or V.17 | 
| 44 | MT3334SMI | 