MultiMobile User Guide
S30= | 0 - 90 | 000 | Inactivity timer. S30 sets length of time, in minutes, that the modem | |||
|
|
| counts when there is no data flow in or out the DTE serial port. A | |||
|
|
| connection is disengaged when the counter reaches the preset | |||
|
|
| value. Set S30 =0 to disable inactivity timer. For buffer mode only. | |||
S36= | 007 | Negotiation fallback options: |
| |||
|
|
| 0, 2 | Hang up |
| |
|
|
| 1, 3 | Fall back to an async connection | ||
|
|
| 4, 6 | Attempt MNP mode. If MNP fails, hang up. | ||
|
|
| 5, 7 | Attempt MNP mode. If MNP fails, fallback to async | ||
|
|
|
|
| connection. |
|
S37= | 000 | S37 sets the desired DCE speed (line speed): | ||||
|
|
| 0 |
| Maximum modem speed | |
|
|
| 2 |
| Attempt 1200/75 bps connection | |
|
|
| 3 |
| Attempt to a 300 bps connection | |
|
|
| 5 |
| Attempt to a 1200 bps connection | |
|
|
| 6 |
| Attempt to a 2400 bps connection | |
|
|
| 7 |
| Attempt to a 4800 bps connection | |
|
|
| 8 |
| Attempt to a 7200 bps connection | |
|
|
| 9 |
| Attempt to a 9600 bps connection | |
|
|
| 10 | Attempt to a 12000 bps connection | ||
|
|
| 11 | Attempt to a 14400 bps connection | ||
|
|
| 12 | Attempt to a 16800 bps connection | ||
|
|
| 13 | Attempt to a 19200 bps connection | ||
|
|
| 14 | Attempt to a 21600 bps connection | ||
|
|
| 15 | Attempt to a 24000 bps connection | ||
|
|
| 16 | Attempt to a 26400 bps connection | ||
|
|
| 17 | Attempt to a 28800 bps connection | ||
|
|
| 18 | Attempt to a 31200 bps connection | ||
|
|
| 19 | Attempt to a 33600 bps connection | ||
S38= | 001 | Sets “downstream” data rate where K56flex provides rates of | ||||
|
|
| 32,000 to 56,000 in 2,000 bps increments, V.90 provides rates of | |||
|
|
| 28,000 to 56,000 bps in increments of 1,333 bps. | |||
|
|
| 0 | = V.90 disabled |
| |
|
|
| 1 | = V.90 autorate | K56flex rates | |
|
|
| 2 | = 28,000 bps | 2 = 32,000 bps | |
|
|
| 3 | = 29,333 bps | 3 = 34,000 bps | |
|
|
| 4 | = 30,666 bps | 4 = 36,000 bps | |
|
|
| 5 | = 32,000 bps | 5 = 38,000 bps | |
|
|
| 6 | = 33,333 bps | 6 = 40,000 bps | |
|
|
| 7 | = 34,666 bps | 7 = 42,000 bps | |
|
|
| 8 | = 36,000 bps | 8 = 44,000 bps | |
|
|
| 9 | = 37,333 bps | 9 = 46,000 bps | |
|
|
| 10 = 38,666 bps | 10 = 48,000 bps | ||
|
|
| 11 = 40,000 bps | 11 = 50,000 bps | ||
|
|
| 12 = 41,333 bps | 12 = 52,000 bps | ||
|
|
| 13 = 42,666 bps | 13 = 54,000 bps | ||
|
|
| 14 = 44,000 bps | 14 = 56,000 bps | ||
|
|
| 15 = 45,333 bps |
| ||
|
|
| 16 = 46,666 bps |
| ||
|
|
| 17 = 48,000 bps |
| ||
|
|
| 18 = 49,333 bps |
| ||
|
|
| 19 = 50,666 bps |
| ||
|
|
| 20 = 52,000 bps |
|
44 | MT5634ZLX/FE |