MultiMobile User Guide

S30=

0 - 90

000

Inactivity timer. S30 sets length of time, in minutes, that the modem

 

 

 

counts when there is no data flow in or out the DTE serial port. A

 

 

 

connection is disengaged when the counter reaches the preset

 

 

 

value. Set S30 =0 to disable inactivity timer. For buffer mode only.

S36=

0-7

007

Negotiation fallback options:

 

 

 

 

0, 2

Hang up

 

 

 

 

1, 3

Fall back to an async connection

 

 

 

4, 6

Attempt MNP mode. If MNP fails, hang up.

 

 

 

5, 7

Attempt MNP mode. If MNP fails, fallback to async

 

 

 

 

 

connection.

 

S37=

0-19

000

S37 sets the desired DCE speed (line speed):

 

 

 

0

 

Maximum modem speed

 

 

 

2

 

Attempt 1200/75 bps connection

 

 

 

3

 

Attempt to a 300 bps connection

 

 

 

5

 

Attempt to a 1200 bps connection

 

 

 

6

 

Attempt to a 2400 bps connection

 

 

 

7

 

Attempt to a 4800 bps connection

 

 

 

8

 

Attempt to a 7200 bps connection

 

 

 

9

 

Attempt to a 9600 bps connection

 

 

 

10

Attempt to a 12000 bps connection

 

 

 

11

Attempt to a 14400 bps connection

 

 

 

12

Attempt to a 16800 bps connection

 

 

 

13

Attempt to a 19200 bps connection

 

 

 

14

Attempt to a 21600 bps connection

 

 

 

15

Attempt to a 24000 bps connection

 

 

 

16

Attempt to a 26400 bps connection

 

 

 

17

Attempt to a 28800 bps connection

 

 

 

18

Attempt to a 31200 bps connection

 

 

 

19

Attempt to a 33600 bps connection

S38=

0-23

001

Sets “downstream” data rate where K56flex provides rates of

 

 

 

32,000 to 56,000 in 2,000 bps increments, V.90 provides rates of

 

 

 

28,000 to 56,000 bps in increments of 1,333 bps.

 

 

 

0

= V.90 disabled

 

 

 

 

1

= V.90 autorate

K56flex rates

 

 

 

2

= 28,000 bps

2 = 32,000 bps

 

 

 

3

= 29,333 bps

3 = 34,000 bps

 

 

 

4

= 30,666 bps

4 = 36,000 bps

 

 

 

5

= 32,000 bps

5 = 38,000 bps

 

 

 

6

= 33,333 bps

6 = 40,000 bps

 

 

 

7

= 34,666 bps

7 = 42,000 bps

 

 

 

8

= 36,000 bps

8 = 44,000 bps

 

 

 

9

= 37,333 bps

9 = 46,000 bps

 

 

 

10 = 38,666 bps

10 = 48,000 bps

 

 

 

11 = 40,000 bps

11 = 50,000 bps

 

 

 

12 = 41,333 bps

12 = 52,000 bps

 

 

 

13 = 42,666 bps

13 = 54,000 bps

 

 

 

14 = 44,000 bps

14 = 56,000 bps

 

 

 

15 = 45,333 bps

 

 

 

 

16 = 46,666 bps

 

 

 

 

17 = 48,000 bps

 

 

 

 

18 = 49,333 bps

 

 

 

 

19 = 50,666 bps

 

 

 

 

20 = 52,000 bps

 