MultiVOIP 200 User Guide
S0=1 | Answer after 1 ring |
S2=43 | Set escape character to + (ASCII 43) |
S3=13 | Set carriage return character to CR (ASCII 13) |
S4=10 | Set line feed character to LF (ASCII 10) |
S5=8 | Set backspace character to BS (ASCII 8) |
S7=45 | Wait 45 seconds for connection before aborting |
S10=20 | Set DCD drop time to 700 ms |
S25=5 | Set DTR detect time to 500 ms |
S32=20 | Set escape sequence guard time to 2 seconds |
S34=2 | Set maximum escape sequence character length |
S50=1 | Caller Line ID enabled |
S52=1 | |
S53=2048 | Maximum X.75 buffer size is 2048 characters |
&S1 | DSR follows DCD |
V1 | Select verbose messages |
!Z=12 | Enable X.75 data protocol |
Profile 4 (&F4) — ML-PPP Asynchronous Operation
AT COMMAND | DESCRIPTION |
&C1 | DCD functions normally |
$D0 | Disable persistent DTR dialing |
&D1 | Hang up when DTR drops |
E1 | Enable command mode echo |
&E4 | Enable hardware flow control |
&E6 | Discard XON/XOFF characters |
&E13 | Enable pacing |
#X0 | Disable Sending Multiple Xoff Characters |
&J0 | Disable Automatic Channel Bundling |
%E1 | Enable +++ escape method |
%E4 | No OK response to +++ or <break> escape |
&R1 | CTS always high |
S0=1 | Answer after 1 ring |
S2=43 | Set escape character to + (ASCII 43) |
S3=13 | Set carriage return character to CR (ASCII 13) |
S4=10 | Set line feed character to LF (ASCII 10) |
S5=8 | Set backspace character to BS (ASCII 8) |
S7=45 | Wait 45 seconds for connection before aborting |
S10=20 | Set DCD drop time to 700 ms |
S25=5 | Set DTR detect time to 500 ms |
S32=20 | Set escape sequence guard time to 2 seconds |
S34=2 | Set maximum escape sequence character length |
S50=1 | Caller Line ID enabled |
S52=1 | |
S53=2048 | Maximum X.75 buffer size 2048 is characters |
&S1 | DSR follows DCD |
V1 | Select verbose messages |
!Z=9 | Enable MLPPP data protocol |
100