DCA-220SSVU — RULES FOR SAFE OPERATION

Maintenance Safety

The electrical voltage required to operate the generator can cause severe injury or even death through physical contact with live circuits. Turn all circuit breakers OFF before performing maintenance on the generator.

NEVER lubricate components or attempt service on a running machine.

ALWAYS disconnect the NEGATIVE battery terminal before performing service on the generator.

Follow all Battery Safety Guidelines listed in this manual when handleing or servicing the generator.

ALWAYS allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts.

ALWAYS service air cleaner frequently to prevent engine malfunction.

WARNING - BURN HAZARDS

To prevent burns, DO NOT touch or open any of the below mentioned components while the engine is

running or immediately after operations. Always allow sufficient time for the engine and generator to cool before performing maintenance.

Radiator Cap - Removing the radiator cap while the engine is hot will result in high pressurized, boiling water to gush out of the radiator, causing severe scalding to any persons in the general area of the generator.

Coolant Drain Plug - Removing the coolant drain plug while the engine is hot will result in hot coolant gushing out of the coolant drain plug, therefore causing severe scalding to any persons in the general area of the generator.

Engine Oil Drain Plug - Removing the engine oil drain plug while the engine is hot will result in hot oil gushing out of the oil drain plug, therefore causing severe scalding to any persons in the general area of the generator.

Battery Safety

Use the following guidelines when handling the battery:

The battery contains acids that can cause injury to the eyes and skin. To avoid eye irritation, always wear safety glasses.

Use well insulated gloves when picking up the battery.

DANGER - EXPLOSION HAZARDS

The risk of an explosion exists when performing service on the battery. To avoid severe injury or DEATH:

DO NOT drop the battery.There is the possibility of risk that the battery may explode.

DO NOT expose the battery to open flames, sparks, cigarettes

etc.The battery contains combustible gases and liquids. If these gases and liquids come in contact with a flame or spark, an explosion could occur.

ALWAYS keep the battery charged. If the battery is not charged a buildup of combustible gas will occur.

ALWAYS keep battery charging and cables in good working condition. Repair or replace all worn cables.

ALWAYS recharge the battery in an vented air environment, to avoid risk of a dangerous concentration of combustible gases.

In case the battery liquid (dilute sulfuric acid) comes in contact with clothing or skin, rinse skin or clothing immediately with plenty of water.

In case the battery liquid (dilute sulfuric acid) comes in contact with your EYES, rinse eyes immediately with plenty of water and contact the nearest doctor or hospital to seek medical attention.

PAGE 12 — DCA-220SSVU— OPERATION AND PARTS MANUAL — REV. #1 (01/20/06)

Page 12
Image 12
Multiquip DCA-220SSVU operation manual Maintenance Safety, Battery Safety

DCA-220SSVU specifications

The Multiquip DCA-220SSVU is a robust and versatile generator, designed for both commercial and industrial applications. It is particularly renowned for its reliability, efficiency, and advanced features tailored to meet the demands of various worksites.

At its core, the DCA-220SSVU is a silent diesel generator, powered by a dependable Yanmar engine. This engine not only provides impressive performance but also ensures durability, making it a popular choice for operations that require continuous power supply. With a power output capacity of 220 kVA, this generator can effortlessly handle heavy-duty equipment and multiple power needs simultaneously.

One of the standout features of the DCA-220SSVU is its sound attenuation technology. Enclosed in a weather-proof canopy, the generator significantly minimizes noise output, making it an ideal option for locations with strict noise regulations, such as residential areas or sensitive environments. The generator operates at a low noise level, allowing it to blend seamlessly into various settings without causing disruption.

The Multiquip DCA-220SSVU also boasts advanced fuel efficiency. It is engineered to consume lesser fuel while providing maximum output, leading to reduced operational costs for users. This efficiency not only helps in cost savings but also minimizes the environmental impact, aligning with contemporary sustainability practices.

Another characteristic that sets the DCA-220SSVU apart is its user-friendly operation. The generator comes equipped with a digital control panel that displays critical information, including voltage, frequency, and runtime. This feature enables operators to monitor performance easily and perform quick troubleshooting when necessary.

Safety is paramount with the DCA-220SSVU, which is equipped with various protective features. These include low oil pressure shutdown, high coolant temperature shutdown, and overcurrent protection, ensuring that the generator operates safely and efficiently under varying load conditions.

Additionally, the generator features a large fuel tank that allows for extended run times, making it suitable for long-term projects or emergency situations. The DCA-220SSVU is engineered for enhanced mobility, thanks to its sturdy frame and integrated lifting points, allowing it to be transported easily across different job sites.

In conclusion, the Multiquip DCA-220SSVU is a powerful, efficient, and quiet generator that incorporates advanced technologies, comprehensive safety features, and user-friendly controls. Ideal for contractors and businesses looking for reliable power solutions, this generator exemplifies Multiquip's commitment to quality and innovation in the construction and industrial sectors.