DCA-25SSAI — ENGINE OPERATING PANEL
The definitions below describe the controls and functions of the
1.Oil Pressure Gauge – Normal operation should be about 25 psi. When starting the generator the oil pressure may read a bit higher, but after the engine warms up the oil pressure should return to normal.
2.Panel light - Normally used in dark places or at night. When activated, panel will luminate. When the generator is not in use, turn the panel light switch to the ‘OFF’ position.
3.WaterTemperature Gauge – During normal operation this gauge be should read between 165o to 215o.
4.Charging Ammeter Gauge – Indicates the current being supplied by the engine’s alternator which provides current for generator’s control circuits and battery charging system.
5.Oil Pressure Indicator - This light will luminate if the oil pressure exceeds 35 psi and will shut off the engine.
6.Water Temperature Indicator - This light will luminate if the water temperature exceeds 2150 and will shut off the engine.
7.Lamp Check Switch (see Control Panel)- Test switch for the lamp indicator on the control panel that the oil pressure and water temperature warning system is working properly.
8.Panel light switch- When activated, will turn on control panel light.
9.Speed Control Handle- To change the speed of the engine from idle to high, pull and turn the handle.
10.
11.Ignition Switch - This switch is used with a key to start, preheat, and stop the engine..
12.Tachometer – Indicates engine speed in RPM’s for 60 Hz operation. This meter should indicate 1800 RPM’s when the rated load is applied. In addition a built in hour meter will record the number of operational hours that the generator has been in use.
PAGE 27 —