ENGINE OPERATING PANEL

1

2

3

4

5

6

7

8

9

 

 

 

 

WATER TEMP.

OIL PRESS.

FUEL LEVEL

 

 

 

 

 

 

AIR FILTER

COOLANT LEVEL

 

 

 

ON

OFF

Figure 5. Engine Operating Panel

The definitions below describe the controls and functions of the Engine Operating Panel (Figure 5).

1.Tachometer — Indicates engine speed in RPM’s for 60 Hz operation. This meter should indicate 1800 RPM’s when the rated load is applied. In addition a built in hour meter will record the number of operational hours that the generator has been in use.

2.Oil Pressure Gauge — During normal operation this gauge be should read between 28 to 85 psi. (193~586 kPa).When starting the generator the oil pressure may read a little higher, but after the engine warms up the oil pressure should return to the correct pressure range.

3.WaterTemperature Gauge — During normal operation this gauge be should read between 167° and 203°F (75°~95°C).

4.Charging Ammeter Gauge — Indicates the current being supplied by the engine’s alternator which provides current for generator’s control circuits and battery charging system.

5.Fuel Gauge — Indicates amount of diesel fuel available.

6.Engine Warning Lamps — There are three engine warning lamps, they are defined as follows:

a.Overheat Lamp — This lamp goes ON when the cooling water temperature rises abnormally. If the lamp goes ON during normal operation of the generator, the emergency shutdown device will stop the engine automatically.

b.Low Oil Pressure Lamp — During normal operation of the generator this lamp should remain OFF. When the

Auto-OFF/Reset-Manual switch is set

to the MANUAL position to start the engine, the lamp will be lit. When the oil pressure rises after start-up the lamp will go OFF. If this lamp is ever lit (ON) during normal operation of the generator, the emergency shutdown device will stop the engine automatically.

c.Low Fuel Level Lamp — When this lamp is ON, it is time to stop the engine and add fuel. Remember to let the engine cool before adding fuel (DCA300SSC only).

d.Air Filter Alarm — When the air filter element is clogged, this lamp goes ON indicating the element should be

immediately cleaned or replaced.

e.Coolant Level Alarm — This lamp goes ON when the coolant level is low. If this lamp goes ON while the engine is

in operation, the emergency shutdown device will automatically stop the engine.

7.Engine Speed Switch — This switch controls the speed of the engine (low/high).

8.Pre-Heat Lamp — When ECU is placed in AUX position, pre-heat lamp will be ON. When pre-heat cycle is completed, lamp will turn OFF.

9.Emergency Stop Button — Push this button inward to stop the engine in the event of an emergency. DO NOT use this button as a means of stopping the engine.

10.Battery Switch — This switch should be set to the ON position during normal operation.When the engine has been stop, place this switch in the OFF position. DO NOT turn this switch during normal operation, it could cause damage to the electrical equipment.

page 20 — DCA300SSC / DCA300SSCU Gen. • operation and parts manual — rev. #1 (08/10/11)

Page 20
Image 20
Multiquip DCA300SSCU manual Engine Operating Panel, Immediately cleaned or replaced

DCA300SSCU specifications

The Multiquip DCA300SSCU is a powerhouse generator designed for both commercial and industrial applications, providing reliable performance in various environments. With a robust design and advanced technology, this generator stands out in the competitive field of portable power solutions.

One of the main features of the DCA300SSCU is its reliable diesel engine, which provides 300 kVA of power. The generator is powered by a fuel-efficient Yanmar engine, known for its durability and low emissions, making it an eco-friendly choice for users who need sustained power without sacrificing environmental standards. This engine is designed to operate efficiently, ensuring lower operational costs over time.

The DCA300SSCU boasts impressive electrical characteristics. It is equipped with a state-of-the-art automatic voltage regulator (AVR) that ensures voltage stability, protecting sensitive electronic equipment from damage due to voltage fluctuations. Additionally, the generator's output can be customized to meet specific needs, offering versatility for various applications ranging from construction sites to events.

This model integrates advanced noise reduction technology, making it quieter than many traditional generators on the market. An enclosed canopy design significantly dampens noise pollution, an essential feature for operation in urban areas or during nighttime events. This focus on reduced sound output allows for greater flexibility in deployment locations without disturbing nearby environments.

Ease of use and maintenance are other key characteristics of the DCA300SSCU. The generator features a user-friendly control panel that makes operation straightforward, even for individuals with minimal experience. Additionally, the maintenance intervals are designed to be manageable, reducing downtime and ensuring that the generator stays operational when it’s needed most.

In terms of mobility, the DCA300SSCU is designed with a trailer for easy transportation, allowing it to be moved from one job site to another with minimal effort. The robust frame and integrated lifting points ensure stability and safety during transit.

In summary, the Multiquip DCA300SSCU is a powerful, efficient, and versatile generator that meets the demands of numerous applications. With its dependable diesel engine, advanced voltage regulation, noise reduction mechanisms, and user-friendly design, it is an ideal choice for professionals seeking a high-performance power solution.