Multiquip DCA300SSCU Check Oil Level, Replacing Oil Filter, Radiator Cleaning, Generator Storage

Models: DCA300SSCU

1 104
Download 104 pages 1.89 Kb
Page 40
Image 40
Check Oil Level

Maintenance

To restart after running out of fuel, turn the switch to the “ON” position for 15-30 seconds. Try again, if needed. This unit is equipped with an automatic air bleeding system.

Check Oil Level

Check the crankcase oil level prior to each use, or when the fuel tank is filled. Insufficient oil may cause severe damage to the engine. Make sure the generator is level. The oil level must be between the two notches on the dipstick as shown in Figure 27.

Replacing Oil Filter

„„Remove the old oil filter.

„„Apply a film of oil to the gasket on the new oil filter. „„Install the new oil filter.

„„After the oil cartridge has been replaced, the engine oil will drop slightly. Run the engine for a while and check for leaks before adding more oil if needed. Clean excessive oil from engine.

Flushing Out Radiator and Replacing Coolant

„„Open both cocks located at the crankcase side and at the lower part of the radiator and drain coolant. Open the radiator cap while draining. Remove the overflow tank and drain.

„„Check hoses for softening and kinks. Check clamps for signs of leakage.

„„Tighten both cocks and replace the overflow tank.

„„Replace with coolant as recommended by the engine manufacturer.

„„Close radiator cap tightly.

„„Flush the radiator by running clean tap water through radiator until signs of rust and dirt are removed. DO NOT clean radiator core with any objects, such as a screwdriver.

Replacing Oil Filter WARNING

Allow engine to cool when flushing out radiator. Flushing the radiator while hot could cause serious burns from water or steam.

Radiator Cleaning

The radiator (Figure 58) should be sprayed (cleaned) with a high pressure washer when excessive amounts of dirt and debris have accumulated on the cooling fins or tube. When using a high pressure washer, stand at least 5 feet (1.5 meters) away from the radiator to prevent damage to the fins and tube.

Figure 58. Radiator Cleaning

Generator Storage

For long term storage of the generator the following is recommended:

„„Drain the fuel tank completely.Treat with a fuel stabilizer if necessary.

„„Completely drain the oil from the crankcase and refill if necessary with fresh oil.

„„Clean the entire generator, internal and external.

„„Cover the generating set and store in a clean, dry place.

„„Disconnect the battery.

„„Make sure engine coolant is at proper level.

„„If generator is mounted on a trailer, jack trailer up and place on blocks so tires do not touch the ground or block and completely remove the tires.

page 40 — DCA300SSC / DCA300SSCU Gen. • operation and parts manual — rev. #1 (08/10/11)