Maintenance

 

Table 12. Inspection/Maintenance

10 Hrs

250 Hrs

500 Hrs

 

1000

 

DAILY

 

Hrs

 

 

 

 

 

 

Check Engine Fluid Levels

X

 

 

 

 

 

Check Air Cleaner

X

 

 

 

 

 

Check Battery Acid Level

X

 

 

 

 

 

Check Fan Belt Condition

X

 

 

 

 

 

Check for Leaks

X

 

 

 

 

 

Check for Loosening of Parts

X

 

 

 

 

 

Replace Engine Oil and Filter * 1

 

X

 

 

 

Engine

Clean Air Filter

 

X

 

 

 

 

Check Fuel Filter/Water Separator Bowl

X

 

 

 

 

 

Clean Unit, Inside and Outside

 

X

 

 

 

 

Change Fuel Filter

 

 

X

 

 

 

Clean Radiator and Check Coolant Protection Level*2

 

 

X

 

 

 

Replace Air Filter Element * 3

 

 

X

 

 

 

Check all Hoses and Clamps * 4

 

 

 

 

X

 

Clean Inside of Fuel Tank

 

 

 

 

X

Generator

Measure Insulation Resistance Over 3M ohms

 

X

 

 

 

Check Rotor Rear Support Bearing

 

 

X

 

 

 

 

 

 

 

*1

Replace engine oil and filter at 100 hours, first time only.

 

 

 

 

 

*2

Add “Supplemental Coolant Additives (SCA’S)” to recharge the engine coolant.

 

 

 

*3

Replace primary air filter element when restriction indicator shows a vacuum of 625 mm (25 in. H20).

 

*4

If blowby hose needs to be replaced, ensure that the slope of the blowby hose is at least a 1/2 inch per foot,

 

with no sags or dips that could collect moisture and/or oil.

 

 

 

 

 

General Inspection

Prior to each use, the generator should be cleaned and inspected for deficiencies. Check for loose, missing or damaged nuts, bolts or other fasteners. Also check for fuel, oil, and coolant leaks. Use Table 12 as a general maintenance guideline Engine Side (Refer to the Engine Instruction Manual)

Air Cleaner

Every 250 hours: Remove air cleaner element (Figure 56) and clean the heavy duty paper element with light spray of compressed air. Replace the air cleaner as needed.

Air Cleaner with Dust Indicator

This indicator (Figure 56) is attached to the air cleaner. When the air cleaner element is clogged, air intake restriction becomes greater and the dust indicator signal shows RED meaning the element needs changing or service. After changing the air element, press the dust indicator button to reset the indicator.

Figure 56. Air Cleaner/Indicator

NOTICE

The air filter should not be changed until the indicator reads “RED”. Dispose of old air filter. It may not be cleaned or reused..

page 38 — DCA300SSC / DCA300SSCU Gen. • operation and parts manual — rev. #1 (08/10/11)

Page 38
Image 38
Multiquip DCA300SSCU manual Maintenance, General Inspection Air Cleaner, Air Cleaner with Dust Indicator

DCA300SSCU specifications

The Multiquip DCA300SSCU is a powerhouse generator designed for both commercial and industrial applications, providing reliable performance in various environments. With a robust design and advanced technology, this generator stands out in the competitive field of portable power solutions.

One of the main features of the DCA300SSCU is its reliable diesel engine, which provides 300 kVA of power. The generator is powered by a fuel-efficient Yanmar engine, known for its durability and low emissions, making it an eco-friendly choice for users who need sustained power without sacrificing environmental standards. This engine is designed to operate efficiently, ensuring lower operational costs over time.

The DCA300SSCU boasts impressive electrical characteristics. It is equipped with a state-of-the-art automatic voltage regulator (AVR) that ensures voltage stability, protecting sensitive electronic equipment from damage due to voltage fluctuations. Additionally, the generator's output can be customized to meet specific needs, offering versatility for various applications ranging from construction sites to events.

This model integrates advanced noise reduction technology, making it quieter than many traditional generators on the market. An enclosed canopy design significantly dampens noise pollution, an essential feature for operation in urban areas or during nighttime events. This focus on reduced sound output allows for greater flexibility in deployment locations without disturbing nearby environments.

Ease of use and maintenance are other key characteristics of the DCA300SSCU. The generator features a user-friendly control panel that makes operation straightforward, even for individuals with minimal experience. Additionally, the maintenance intervals are designed to be manageable, reducing downtime and ensuring that the generator stays operational when it’s needed most.

In terms of mobility, the DCA300SSCU is designed with a trailer for easy transportation, allowing it to be moved from one job site to another with minimal effort. The robust frame and integrated lifting points ensure stability and safety during transit.

In summary, the Multiquip DCA300SSCU is a powerful, efficient, and versatile generator that meets the demands of numerous applications. With its dependable diesel engine, advanced voltage regulation, noise reduction mechanisms, and user-friendly design, it is an ideal choice for professionals seeking a high-performance power solution.