Safety Information

FUel SaFetY

Danger

„Do not start the engine near spilled fuel or combustible fl uids. Diesel fuel is extremely fl ammable and its vapors can cause an explosion if ignited.

„alWaYS refuel in a well-ventilated area, away from sparks and open fl ames.

„alWaYS use extreme caution when working with flammable liquids.

„Do not fi ll the fuel tank while the engine is running or hot.

„Do not overfi ll tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system.

„Store fuel in appropriate containers, in well-ventilated areas and away from sparks and fl ames.

„never use fuel as a cleaning agent.

„Do not smoke around or near the equipment. Fire or explosion could result

from fuel vapors or if fuel is spilled on a hot engine.

toWing SaFetY

CaUtion

„Check with your local county or state safety towing regulations, in addition to meeting

Department of Transportation (DOT) SafetyTowing Regulations, before towing your generator.

„Refer to MQ Power trailer manual for additional safety information.

„In order to reduce the possibility of an accident while transporting the generator on public roads, alWaYS make sure the trailer that supports the generator and the towing vehicle are mechanically sound and in good operating condition.

„alWaYS shutdown engine before transporting

„Make sure the hitch and coupling of the towing vehicle are rated equal to, or greater than the trailer “gross vehicle weight rating.”

„alWaYS inspect the hitch and coupling for wear. never tow a trailer with defective hitches, couplings, chains, etc.

„Check the tire air pressure on both towing vehicle and trailer. Trailer tires should be inflated to 50 psi cold. Also check the tire tread wear on both vehicles.

„alWaYS make sure the trailer is equipped with a safety chain.

„alWaYS properly attach trailer’s safety chains to towing vehicle.

„alWaYS make sure the vehicle and trailer directional, backup, brake and trailer lights are connected and working properly.

„DOT Requirements include the following:

Connect and test electric brake operation.

Secure portable power cables in cable tray with tie wraps.

„The maximum speed for highway towing is 55 mpH unless posted otherwise. Recommended off-road towing is not to exceed 15 mpH or less depending on type of terrain.

„Avoid sudden stops and starts.This can cause skidding, or jack-knifi ng. Smooth, gradual starts and stops will improve towing.

„Avoid sharp turns to prevent rolling.

„Trailer should be adjusted to a level position at all times when towing.

„Raise and lock trailer wheel stand in up position when towing.

„Place chock blocks underneath wheel to prevent rolling while parked.

„Place support blocks underneath the trailer’s bumper to prevent tipping while parked.

„Use the trailer’s swivel jack to adjust the trailer height to a level position while parked.

DCA300SSC / DCA300SSCU Gen. • operation and parts manual — rev. #1 (08/10/11) — page 9

Page 9
Image 9
Multiquip DCA300SSCU manual FUel SaFetY, ToWing SaFetY, „ never use fuel as a cleaning agent

DCA300SSCU specifications

The Multiquip DCA300SSCU is a powerhouse generator designed for both commercial and industrial applications, providing reliable performance in various environments. With a robust design and advanced technology, this generator stands out in the competitive field of portable power solutions.

One of the main features of the DCA300SSCU is its reliable diesel engine, which provides 300 kVA of power. The generator is powered by a fuel-efficient Yanmar engine, known for its durability and low emissions, making it an eco-friendly choice for users who need sustained power without sacrificing environmental standards. This engine is designed to operate efficiently, ensuring lower operational costs over time.

The DCA300SSCU boasts impressive electrical characteristics. It is equipped with a state-of-the-art automatic voltage regulator (AVR) that ensures voltage stability, protecting sensitive electronic equipment from damage due to voltage fluctuations. Additionally, the generator's output can be customized to meet specific needs, offering versatility for various applications ranging from construction sites to events.

This model integrates advanced noise reduction technology, making it quieter than many traditional generators on the market. An enclosed canopy design significantly dampens noise pollution, an essential feature for operation in urban areas or during nighttime events. This focus on reduced sound output allows for greater flexibility in deployment locations without disturbing nearby environments.

Ease of use and maintenance are other key characteristics of the DCA300SSCU. The generator features a user-friendly control panel that makes operation straightforward, even for individuals with minimal experience. Additionally, the maintenance intervals are designed to be manageable, reducing downtime and ensuring that the generator stays operational when it’s needed most.

In terms of mobility, the DCA300SSCU is designed with a trailer for easy transportation, allowing it to be moved from one job site to another with minimal effort. The robust frame and integrated lifting points ensure stability and safety during transit.

In summary, the Multiquip DCA300SSCU is a powerful, efficient, and versatile generator that meets the demands of numerous applications. With its dependable diesel engine, advanced voltage regulation, noise reduction mechanisms, and user-friendly design, it is an ideal choice for professionals seeking a high-performance power solution.