RULES FOR SAFE OPERATION

NEVER pump volatile, flammable or low flash point fluids. These fluids could ignite or explode.

NEVER pump corrosive chemicals or water containing toxic substances. These fluids could create serious health and environmental hazards. Contact local authorities for assistance.

NEVER open the volute cover during operation or start the pump with the cover off. The rotating impeller inside the pump can cut or sever objects caught in it.

NEVER block or restrict flow from discharge hose. Remove kinks from discharge line before starting pump. Operation with a blocked discharge line can cause water inside pump to overheat.

NEVER run engine without air cleaner. Severe engine damage may occur.

ALWAYS read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

ALWAYS be sure the operator is familiar with proper safety precautions and operations techniques before using pump.

ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

Refer to the Engine Owner's Manual for engine technical questions or information.

In winter, drain water from pump housing to prevent freezing.

ALWAYS make sure pump is correctly secured to the trailer. Check all supports attaching the pump to the trailer and make sure they are tight.

ALWAYS make sure that the pump's trailer is placed on solid level ground so that it cannot slide or shift around, endangering workers. Deploy jack stands for stabilization. Place blocks under the trailer's bumper to make it level (prevents tipping), and use a chocked block underneath the wheels to prevent rolling. Also keep the immediate area free of bystanders.

HighTemperatures – Allow the engine to cool before adding fuel or performing service and maintenance functions. Contact with hot components can cause serious burns.

RULES FOR SAFE OPERATION

Maintenance Safety

NEVER lubricate components or attempt service on a running machine.

ALWAYS allow the machine a proper amount of time to cool before servicing.

Keep the machinery in proper running condition.

Fix damage to the machine immediately and always replace broken parts.

Dispose of hazardous waste properly.Examples of potentially hazardous waste are used motor oil, fuel and fuel filters.

DO NOT use food or plastic containers to dispose of hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground, down a drain or into any water source.

Lifting

The pump has an operating weight of 3180 lbs. (1,442 kg) or more . Use lifting equipment with a rated capacity of at least 14,000 lbs. (6,350 kg). Remove suction & discharge hoses/ pipes before lifting.

Add 1000 lbs. (454 kg.) to the

NOTE operating weight for a full tank of fuel, 140 gallons (530 liters).

EMERGENCIES

ALWAYS know the location of the nearest fire extinguisher and first aid kit.

In emergencies always know the location of the nearest phone or keep a phone on the job site. Also know the phone numbers of the nearest ambulance, doctor and fire department. This information will be invaluable in the case of an emergency.

DRY PRIME PUMP — OPERATION AND PARTS MANUAL — REV. #3 (10/06/08) — PAGE 11