Ping a Host

Command Name

ping

Description

Ping a host

Syntax

ping [-t] [-n count] [-w timeout] target_name

Parameters

target_name

 

IP Address or host name.

 

-t

 

Ping the specified host until stopped.

 

To see statistics and continue - type Space;

 

To stop - type Control-C.

 

-n count

 

Number of echo requests to send.

 

-w timeout

 

Timeout in milliseconds to wait for each reply.

Example

N-TRON/Admin> ping 192.168.1.119

 

 

N-TRON/Admin> ping –n 6 192.168.1.119

 

 

N-TRON/Admin> ping –t 192.168.1.119

 

 

N-TRON/Admin> ping –w 2000 192.168.1.119

 

Reply from 192.168.1.119: time=970ms

 

Reply from 192.168.1.119: time<10ms

 

Reply from 192.168.1.119: time<10ms

 

Ping statistics for 192.168.1.119:

 

Packets: Sent = 4, Received = 3, Lost = 1 (25% loss)

 

Approximate round trip times in milliseconds:

 

Minimum = 0ms, Maximum = 970ms, Average = 320ms

Notes

 

Reset the Switch

 

Command Name

reset

Description

Reset (reboot) the switch

Syntax

reset

Parameters

None

Example

N-TRON/Admin> reset

 

Performing Soft-Reset...

 

Notes

 

Show or Clear the Last System Error

Command Name

syserr

Description

Show or clear the last system error

 

If clear is not supplied, then the last system error is displayed.

Syntax

syserr [clear]

Parameters

clear

 

Clear the last system error.

Example

N-TRON/Admin> syserr

 

Last System Error: None.

 

N-TRON/Admin> syserr clear

 

Last System Error: Cleared.

Notes

 

Revision 071108