3)Control sequence
1)The command from a computer to the Plasma monitor will take 400ms.
2)The Plasma monitor will send a return command 400ms* after it has received an encode. If the command is not received correctly,
the Plasma monitor will not send the return command.
3)The personal computer checks the command and confirms if the command which has been sent has been executed or not.
4)This Plasma monitor sends various codes other than the return code. When sending a control sequence via
*The sending time of the return command may be delayed depending on the monitor’s current activity (changing of the input signal, etc.).
[Example] Turn the power ON. (' ' is for ASCII code)
Sending commands | Status code from | Meaning |
from the PC etc. | Plasma monitor |
|
|
|
|
30 30 21 0D |
| Command for |
'0' '0' '!' ' ' |
| POWER ON |
|
|
|
| 30 30 21 0D | Command received |
| '0' '0' '!' ' ' | (Command echo back) |
|
|
|
4) Operation commands
Operation commands execute the basic operation setting of this Plasma monitor. It may not operate when changing the signal:
Operation | ASCII |
| HEX |
|
|
|
|
|
|
POWER ON | ! |
| 21h |
|
|
|
|
|
|
POWER OFF | " |
| 22h |
|
|
|
|
|
|
INPUT VIDEO1 | _v1 | 5Fh | 76h | 31h |
|
|
|
|
|
INPUT VIDEO2 | _v4 | 5Fh | 76h | 34h |
|
|
|
|
|
INPUT | _v3 | 5Fh | 76h | 33h |
|
|
|
|
|
INPUT DVD/HD1 | _v2 | 5Fh | 76h | 32h |
|
|
|
|
|
INPUT DVD/HD2 | _v5 | 5Fh | 76h | 35h |
|
|
| ||
INPUT SCART3 | _v6 | 5Fh 76h 36h | ||
|
|
|
|
|
INPUT VGA | _r2 | 5Fh | 72h | 32h |
|
|
| ||
INPUT RGBHV | _r3 | 5Fh 72h 33h | ||
|
|
| ||
INPUT DVI | _r1 | 5Fh 72h 31h | ||
|
|
|
|
|
•POWER OFF command should not be used less than 1 minute after the power is turned on.
•POWER ON command should not be used less than 1 minute after the power is turned off.
English