NEC 5800, 120Mf Specifications, Major, Minor, Standard, Remarks, classification, dB operating

Models: 120Mf 5800

1 68
Download 68 pages 4.64 Kb
Page 20
Image 20
SPECIFICATIONS

2-2 Overview

SPECIFICATIONS

The table below lists the general specifications of the unit.

Major

Minor

Standard

Remarks

classification

classification

 

 

Input power

Power supply

Single phase, 2-pole grounding

The power supply itself

 

Voltage

100 to 240 VAC±10%

is capable between 100

 

 

 

to 240 VAC, however,

 

Frequency

50±1 Hz or 60±1 Hz

 

the value at the left is

 

Waveform

10%

used as a unit

 

distortion

 

specification.

Power

Input current

5.3 A

AC100V

consumption

Apparent power

530 VA

 

 

Active power

520 W

 

Temperature and

Temperature

10 to 35oC

No condensation is

humidity

Humidity

20 to 80%RH

allowed

Noise

POWER level

62.8 dB (operating)

 

 

 

60.9 dB (standby)

 

 

Sound pressure

52.9 dB (operating)

 

 

level

51.7 dB (standby)

 

Page 20
Image 20
NEC 5800, 120Mf manual Specifications, Major, Minor, Standard, Remarks, classification, dB operating, dB standby