NEC 120Mf, 5800 manual Updating SDR FW, Mounting a Heat Sink on the CPU, Removing the Motherboard

Models: 120Mf 5800

1 68
Download 68 pages 4.64 Kb
Page 49
Image 49
Updating SDR FW

6-11 Installing Optional Internal Devices

Updating SDR FW

Refer to the update procedure document of the Motherboard maintenance parts.

Mounting a Heat Sink on the CPU

Refer to the Express Server User’s guide.

Removing the Motherboard

a.Turn off the power, and then pull the AC cable out.

b.Remove a side cover.

c.Extract heat sinks, CPUs, memory boards, PCI boards, etc.

The following procedure explains how to remove a heat sink. (Please DO NOT pull up straight to draw out a heat sink. If it is removed that way, CPU may be taken out with heat sink. )

1.When removing retention, use a minus driver or the tool only for removal of a clip, hook on a hole and remove.

2.Remove the retention.

3.Please turn the heat sink to the right and left lightly to remove it. Please DO NOT pull up straight.

To remove a CPU, follow the procedure for installing a heat sink in reverse order.

Page 49
Image 49
NEC 120Mf, 5800 manual Updating SDR FW, Mounting a Heat Sink on the CPU, Removing the Motherboard