| Description | Cause | Action |
| |||
| 0B02 | Rebooted during OS | The system |
|
|
|
|
|
| Runtime. | during OS Running |
|
|
|
|
| 0B1B | PCI System Error on | A PCI system error |
|
|
|
|
|
| Bus/Device/Function | occurred on the bus, |
|
|
|
|
|
|
| device, or function. |
|
|
|
|
| 0B1C | PCI Parity Error on | A PCI parity error |
|
|
|
|
|
| Bus/Device/Function | occurred on the bus, |
|
|
|
|
|
|
| device, or function. |
|
|
|
|
|
|
|
|
|
|
|
|
| 0B22 | Processors are | Failure of a processor | Processor errors | 1. | Replace CPU |
|
|
| installed out of order. |
|
| 2. | Replace Motherboard |
|
| 0B28 | Unsupported | Unsupported processor |
|
|
|
|
|
| Processor detected on | mounted as processor 1. |
|
|
|
|
|
| Processor 1 |
|
|
|
|
|
| 0B29 | Unsupported | Unsupported processor |
|
|
|
|
|
| Processor detect on | mounted as processor 2. |
|
|
|
|
|
| Processor 2 |
|
|
|
|
|
| 0B30 | Fan 1 Alarm occurred. | Fan errors | 1. Fan is blocked | 1. | Check fan connection |
|
| 0B31 | Fan 2 Alarm occurred. |
| 2. Fan failed | 2. | Clean fan |
|
|
|
|
| 3. Motherboard failed | 3. | Replace fan |
|
| 0B32 | Fan 3 Alarm occurred. |
|
| |||
|
|
| 4. | Replace Motherboard |
| ||
| 0B33 | Fan 4 Alarm occurred. |
|
|
| ||
|
|
|
|
|
| ||
| 0B34 | Fan 5 Alarm occurred. |
|
|
|
|
|
| 0B35 | Fan 6 Alarm occurred. |
|
|
|
|
|
| 0B50 | CPU #1 with error | CPU #1 was degraded | 1. CPU# 1 failed | 1. | Replace CPU #1 |
|
|
| taken off line | due to an error detected | 2. Motherboard failed | 2. | Replace Motherboard |
|
|
|
| for CPU #1. |
|
|
|
|
| 0B51 | CPU #2 with error | CPU #2 was degraded | 1. CPU# 2 failed | 1. | Replace CPU #2 |
|
|
| taken off line | due to an error detected | 2. Motherboard failed | 2. | Replace Motherboard |
|
|
|
| for CPU #1. |
|
|
|
|
| 0B5F | Forced to use | A CPU error was |
| 1. | Replace CPU |
|
|
| Processor with error | detected. |
| 2. | Replace Motherboard |
|
| 0B60 | DIMM group #1 has | A memory error was |
| 1. Replace Memory #1 |
| |
|
| been disabled | detected. Memory #1 is |
| 2. | Replace Motherboard |
|
|
|
| degraded. |
|
|
|
|
| 0B61 | DIMM group #2 has | A memory error was |
| 1. Replace Memory #2 |
| |
|
| been disabled | detected. Memory #2 is |
| 2. | Replace Motherboard |
|
|
|
| degraded. |
|
|
|
|
| 0B62 | DIMM group #3 has | A memory error was |
| 1. Replace Memory #3 |
| |
|
| been disabled | detected. Memory #3 is |
| 2. | Replace Motherboard |
|
|
|
| degraded. |
|
|
|
|
| 0B70 | The error occurred | An error was detected in | 1. SMBus Device | 1. | Turn off AC |
|
|
| during temperature | the course of thermal | failed | 2. | Check cable |
|
|
| sensor reading. | error detection. | 2. SMBus Cable | 3. | Replace Motherboard |
|
|
|
|
| failed |
|
|
|
| 0B71 | System Temperature | A thermal error was |
| 1. | Clean fan |
|
|
| out of the range. | detected. |
| 2. | Replace fan |
|
|
|
|
|
| 3. | Replace boards |
|
| 0B74 | The error occurred | An error occurred while | Motherboard failed | 1. Turn off AC |
| |
|
| during voltage sensor | detecting the voltage. |
| 2. | Check connection of |
|
|
| reading. |
|
|
| internal cables |
|