NEC 120Mf, 5800 manual Troubleshooting

Models: 120Mf 5800

1 68
Download 68 pages 4.64 Kb
Page 29
Image 29

 

 

 

 

 

4-5 Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

On-screen error message

Description

Cause

Action

 

0B94

IPMB signal lines do

An SMC (Sattelite

 

 

 

 

 

not respond.

Management

 

 

 

 

 

 

Controller) error

 

 

 

 

0B95

BMC FRU device

An error of the SROM

 

 

 

 

 

failure.

that stores the chassis

 

 

 

 

 

 

information

 

 

 

 

0B96

BMC SDR Repository

The access error to

 

 

 

 

 

failure.

FMEM sector in which

 

 

 

 

 

 

SDR information was

 

 

 

 

 

 

stored

 

 

 

 

0B97

BMC SEL device

A BMC device (chip)

 

 

 

 

 

failure.

failure

 

 

 

 

 

 

 

 

 

 

0B98

BMC RAM test error.

BMC RAM error

BMC failed

1. Turn off AC and re-start

 

0B99

BMC Fatal hardware

BMC error

 

2. Replace Motherboard

 

 

error.

 

 

 

 

 

0B9A

Management

BMC error

 

 

 

 

 

controller not

 

 

 

 

 

 

responding

 

 

 

 

 

0B9B

Private I2C bus not

It-less answers from

 

 

 

 

 

responding.

private I2 C bus

 

 

 

 

0B9C

BMC internal

BMC error

 

 

 

 

 

exception

 

 

 

 

 

0B9D

BMC A/D timeout

BMC error

 

 

 

 

 

error.

 

 

 

 

 

0B9E

SDR repository

The error of BMC or

 

 

 

 

 

corrupt.

the data of SEL is

 

 

 

 

 

 

destroyed.

 

 

 

 

0B9F

SEL corrupt.

The error of BMC or

 

 

 

 

 

 

the data of SEL is

 

 

 

 

 

 

destroyed.

 

 

 

 

0BB0

SMBIOS - SROM

Incorrect SROM data

Turn off AC and

1. Turn off AC and re-start

 

 

data read error.

read

replace CPU#1

2. Replace boards

 

0BB1

SMBIOS - SROM

Incorrect SROM data

 

 

 

 

 

data checksum bad.

checksum

 

 

 

 

 

 

 

 

 

 

0BC0

POST detected startup

Processor 1 error

 

Turn off AC and replace

 

 

failure of 1st

 

 

CPU#1

 

 

Processor.

 

 

 

 

 

0BC1

POST detected startup

Processor 2 error

 

Turn off AC and replace

 

 

failure of 2nd

 

 

CPU#2

 

 

Processor.

 

 

 

 

 

0BD0

1st SMBus device

A device-less answers

SMBus Access error

1. Turn off AC and re-start

 

 

address not

to 1st SMBus access.

 

2. Replace boards

 

 

acknowledged.

 

 

3. Replace internal cables

 

0BD1

1st SMBus device

The error was detected

 

 

 

 

 

Error detected.

to 1st SMBus access

 

 

 

 

 

 

 

 

 

 

 

0BD2

1st SMBus timeout.

The timeout occurred to

 

 

 

 

 

 

1st SMBus access.

 

 

 

Page 29
Image 29
NEC 120Mf, 5800 manual Troubleshooting