4-4 Troubleshooting

4-4 Troubleshooting

On-screen error message

Description

Cause

Action

0B75

System Voltage out of

A system voltage error

1. SMBus Device

internal cables

 

the range.

was detected.

failed

3. Replace internal cables

 

 

 

2. SMBus Cable

4. Replace boards

 

 

 

failed

 

0B78

The error occurred

An error was detected

1. SMBus Device

1. Turn off AC

 

during fan sensor

during fan sensor

failed

2. Check cable

 

reading.

reading.

2. SMBus Cable

3. Replace Motherboard

0B7C

The error occurred

The error was detected

failed

 

 

during redundant

while having constituted

 

 

 

power module

the redundant power

 

 

 

confirmation.

supply.

 

 

 

 

 

 

 

0B7D

The normal operation

Basic power supply

Power supply error

Replace a power supply

 

can't be guaranteed

composition required

 

 

 

with use of only one

for this equipment is not

 

 

 

PSU.

filled.

 

 

0B80

BMC Memory Test

A BMC device (chip)

BMC failed

1. Turn off AC and re-start

 

Failed.

failure

 

2. Replace Motherboard

0B81

BMC Firmware Code

 

 

 

 

Area CRC check

 

 

 

 

failed.

 

 

 

0B82

BMC core hardware

 

 

 

 

failure.

 

 

 

0B83

BMC IBF or OBF

Access to the BMC

 

 

 

check failed.

address failed.

 

 

 

 

 

 

0B8A BMC SEL area full.

An opening is not in the

 

 

 

 

capacity of SEL.

 

 

0B8B

BMC progress check

BMC check was

 

 

 

timeout.

interrupted temporarily.

 

 

0B8C

BMC command

BMC command access

 

 

 

access failed.

failed.

 

 

0B8D

Could not redirect the

Console redirection

 

 

 

console - BMC Busy -

cannot be carried out

 

 

 

 

(BMC Busy)

 

 

0B8E

Could not redirect the

Console redirection

 

 

 

console - BMC Error -

cannot be carried out

 

 

 

 

(BMC error)

 

 

0B8F

Could not redirect the

Console redirection

 

 

 

console - BMC

cannot be carried out

 

 

 

Parameter Error -

(BMC Parameter error)

 

 

0B90

BMC Platform

A BMC device (chip)

BMC failed

1. Turn off AC and re-start

 

Information Area

failure

 

2. Replace Motherboard

 

corrupted.

 

 

 

 

 

 

 

 

0B91

BMC update firmware

 

 

 

 

corrupted.

 

 

 

 

 

 

 

 

0B92

Internal Use Area of

An error of the SROM

1. SROM failed

 

 

BMC FRU corrupted

that stores the chassis

2. BMC failed

 

 

 

information

 

 

0B93

BMC SDR Repository

A BMC device (chip)

BMC failed

 

 

empty.

failure

 

 

Page 28
Image 28
NEC 5800, 120Mf manual Troubleshooting