6. Appendix

6-6. Specifications

Model No.

 

NC2500S

 

 

Projection method

 

3 chip DMD reflector method (DLP® method)

Panel resolution

 

2048 x 1080

 

 

Lamp type

 

4.5 kW to 7 kW xenon lamp (Note)

 

Screen sizes

 

15 m to 25 m (Width) (Depends on setup conditions)

Contrast ratio

 

2000:1 or above

 

Lens adjustment function

Motorized lens shift (vertical/horizontal), motorized zoom, motorized focus, douser

Signal input terminal

RGB DIGITAL (2) DVI-D 24pinTMDS specification

 

 

 

SDI (2) BNCSMPTE 292M

 

External Control

 

RS232C (1) D-sub 9 pin

 

 

 

 

Remote control

 

 

 

 

LAN port (RJ-45) x 2

 

 

 

 

USB port (type A)

 

 

 

 

GPIO port (D-sub 37 pin)

 

 

 

 

PC card slot (1) PCMCIA type II, card bus

 

 

 

Interlock terminal

 

Power supply

 

Projector head

AC200 to 240V, 50/60 Hz single phase

 

voltage

 

Lamp power supply

AC200-230V, 50/60Hz Three-phase (Star connection)

 

 

 

AC380-415V, 50/60Hz Three-phase (Star connection) Switch type

Input current

 

Projector head

5A

 

 

 

 

Lamp power supply

28A (200 to 230V), 16A (380 to 415V)

 

Power

 

Projector head

0.95kW

 

 

consumption

 

Lamp power supply

8kW

 

 

Cooling method

 

Cooling fluid system, Cooling air system (includes dust filter)

Noise level

 

Less than 65 dB

 

Installation

 

Orientation:Desktop/front, Desktop/rear

 

Dimensions

 

Projector head

700 mm (W) x 1100 mm (D) x 503 mm (H) (Does not include protruding portions Includes foot)

 

 

Lamp power supply

596 mm (W) x 397 mm (D) x 471 mm (H)

 

Net weight

 

Projector head

115 kg (Excluding lens)

 

 

 

Lamp power supply

50.5kg

 

 

Environment

 

Operating temperature: 5 to 35˚C

 

 

 

 

Operating humidity: 10 to 85% (non-condensing)

 

 

 

Storage temperature: -10 to 50˚C

 

 

 

 

Storage humidity: 10 to 85% (non-condensing)

Regulations

 

 

<Safety>

<EMC>

 

 

 

USA

UL60950-1

FCC Class A

 

 

 

Canada

CSA60950-1

ICES-003 Class A

 

 

 

Europe

EN60950-1

EN55022 Class A

 

 

 

 

 

EN55024

 

 

 

Oceania

IEC60950-1

 

 

 

 

 

AS/NZS CISPR. 22

Class A

 

 

 

Japan

J60950

VCCI Class A

 

 

 

Asia

IEC60950-1

CISPR. 22

(Note) Using any lamp other than NEC’s optional lamps will result in lower brightness compared to NEC optional lamps. If brightness is important to you, it is recommended that you use NEC’s optional lamps.

NEC will post information on its homepage regarding installable lamps, other than NEC’s optional lamps. Note that NEC does not guarantee performance and reliability when lamps other than NEC’s optional lamps are installed.

* Note that these specifications and design can change without prior notice.

46