NEC NDA-30135 manual User-Defined, OAI1TCP

Models: NDA-30135

1 22
Download 22 pages 30.98 Kb
Page 14
Image 14

INSTALLATION & CONFIGURATION

Attendant Monitor Operations Manual

OAI-Conf Settings Use the OAI-Confcommand on the APM Configuration Entry screen to make the necessary parameter entries. For parameters shown with an asterisk (*) in the table below, make entries exactly as shown. The other parameters are shown with sample entries that may be changed to meet site requirements. Use the instructions provided for this option in the APM Operations Manual:

Parameter

Entry Value

Description

 

 

 

Database Name #1*

/oai/db/cur/tenants

The path name of the tenant number

 

 

database.

 

 

 

Database Name #2*

/oai/db/cur/Attmon

The path name of the Attendant Monitor

 

 

database.

 

 

 

Timeout Value #1

0

Unused

 

 

 

Timeout Value #2

0

Unused

 

 

 

Tenant Number

1

Default Tenant Number

 

 

 

Source Link Name

OAI1TCP

Port on the source side of the

 

 

communication link. Entry should match a

 

 

link name in the APM system

 

 

configuration file.

 

 

 

Destination Link Name

PBX1TCP

Port on the destination side of the

 

 

communication link. Entry should match a

 

 

link name in the APM system

 

 

configuration file.

 

 

 

Association Recovery

30

Number of seconds Attendant Monitor

 

 

waits before trying to reestablish an

 

 

association with the NEAX that has been

 

 

released.

 

 

 

User-Defined

No user defined parameters are used in Attendant Monitor. Therefore, all user

Parameters

defined parameters are blank.

Continue to the next page for Database Support...

Page 10

NDA-30135 Revision 1

Page 14
Image 14
NEC NDA-30135 manual User-Defined, OAI1TCP