***Following command also can be used for to keep backward compatibility, in order to write the setting of the Schedule.
1) The controller requests the monitor to write Schedule.
Header | Message | Check code | Delimiter |
| BCC | CR |
OFF
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
Message
STX (02h): Start of Message
ON_HOUR: Turn on time (hour)
ON_MIN: Turn on time (minute)
OFF_HOUR: Turn off time (hour)
OFF_MIN: Turn off time (minute)
'3'-'B'(33h, 42h): 59 (=3Bh)
INPUT: Timer input
*Please select active input on your system (setting).
*If you select inactive input here, the input change execution will be ignored.
WD: Week setting bit 0: Monday bit 1: Tuesday bit 2: Wednesday bit 3: Thursday
(33/50)