Check code

BCC: Block Check Code

Refer to the section 4.5 “Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

Step 2. The monitor replies with current Brightness setting and capability to support this operation.

 

Header

 

 

Message

Check code

Delimiter

SOH-'0'-'0'-Monitor ID-'D'-'1'-'2'

 

STX-'0'-'0'-'0'-'0'-'1'-'0'-'0'-'0'

BCC

 

 

CR

 

 

 

 

-'0'-'0'-'6'-'4'-'0'-'0'-'3'-'2'-ETX

 

 

 

 

 

 

 

Header

 

 

 

 

 

 

 

 

 

SOH (01h): Start Of Header

 

 

 

 

 

 

 

 

 

'0' (30h): Reserved

 

 

 

 

 

 

 

 

 

'0' (30h): Message receiver is the controller.

 

 

 

 

 

 

 

Monitor ID: Indicate a replying Monitor ID.

 

 

 

 

 

 

 

Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.

 

 

 

'D' (44h): Message Type is "Get parameter reply".

 

 

 

 

 

 

 

'1'-'2' (31h, 32h): Message length is 18 bytes.

 

 

 

 

 

 

 

Message

 

 

 

 

 

 

 

 

 

STX (02h): Start of Message

 

No error.

 

 

 

 

 

 

 

'0'-'0' (30h, 30h): Result code.

 

 

 

 

 

 

 

'0'-'0' (30h, 30h): Operation code page number is 0.

 

 

 

 

 

 

 

'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).

 

 

 

 

 

 

 

'0'-'0' (30h, 30h): This operation is "Set parameter" type.

 

 

 

 

 

 

 

'0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Brightness max value is 100(0064h).

 

 

 

 

 

'0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): Current Brightness setting is 50(0032h) .

 

 

 

ETX (03h): End of Message

 

 

 

 

 

 

 

 

 

Check code

 

 

 

 

 

 

 

 

 

BCC: Block Check Code

 

 

 

 

 

 

 

 

 

Refer to the section 4.5 “Check code” for a BCC calculation.

 

 

 

 

 

 

 

Delimiter

 

 

 

 

 

 

 

 

 

CR (0Dh): End of packet

 

 

 

 

 

 

 

 

 

Step 3. The controller request the monitor to change the Brightness setting

 

 

 

 

 

Header

 

Message

 

 

Check

 

Delimiter

 

 

 

 

 

code

 

 

 

SOH-'0'-Monitor ID-'0'-'E'-'0'-'A'

 

STX-'0'-'0'-'1'-'0'-'0'-'0'-'5'-'0'-ETX

 

BCC

 

CR

 

Header

SOH (01h): Start Of Header

'0' (30h): Reserved

Monitor ID: Specify the Monitor ID of which you want to change a setting. Ex.) If Monitor ID is '1', specify 'A'.

'0' (30h): Message sender is the controller .

'E' (45h): Message Type is "Set parameter command".

'0'-'A' (30h, 41h): Message length is 10 bytes.

Message

STX (02h): Start of Message

'0'-'0' (30h, 30h): Operation code page number is 0.

'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).

'0'-'0'-'5'-'0' (30h, 30h, 35h, 30h): Set Brightness setting 80(0050h).

ETX (03h): End of Message

Check code

BCC: Block Check Code

Refer to the section 4.5 “Check code” for a BCC calculation.

Delimiter

(12/50)

Page 12
Image 12