CR (0Dh): End of packet

Step 4. The monitor replies with a message for confirmation.

Header

Message

Check code

Delimiter

SOH-'0'-'0'- Monitor ID -'F'-'1'-'2'

STX-'0'-'0'-'0'-'0'-'1'-'0'—'0'-'0'-'0'

BCC

CR

-'0'-'6'-'4'-'0'-'0'-'5'-'0'-ETX

Header

SOH (01h): Start Of Header

'0' (30h): Reserved

'0' (30h): Message receiver is the controller.

Monitor ID: Indicate a replying Monitor ID.

Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.

'F' (46h): Message Type is "Set parameter reply".

'1'-'2' (31h, 32h): Message length is 18 bytes.

Message

STX (02h): Start of Message

'0'-'0' (30h, 30h): Result code. No error.

'0'-'0' (30h, 30h): Operation code page number is 0.

'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).

'0'-'0' (30h, 30h): This operation is "Set parameter" type.

'0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Brightness max value is 100(0064h).

'0'-'0'-'5'-'0' (30h, 30h, 35h, 30h): Received a Brightness setting was 80(0050h) .

ETX (03h): End of Message

Check code

BCC: Block Check Code

Refer to the section 4.5 “Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

Repeat Step 1 and Step 2, if you need to check the Brightness setting. (Recommended) Step 5. Request the monitor to store the Brightness setting. (Save Current Settings Command)

Header

Message

Check code

Delimiter

SOH-'0'-Monitor ID-'0'-'A'-'0'-'4'

STX-'0-'C'-ETX

BCC

CR

Header

SOH (01h): Start Of Header

'0' (30h): Reserved

Monitor ID: Specify the Monitor ID which you want to store the setting. Ex.) If Monitor ID is '1', specify 'A'.

'0' (30h): Message sender is the controller.

'A' (41h): Message type is "Command".

'0'-'4' (30h, 34h): Message length is 4 bytes.

Message

STX (02h): Start of Message

'0'-'C' (30h, 43h): Command code is 0Ch as "Save current settings".

ETX (03h): End of Message

Check code

BCC: Block Check Code

Refer to the section 4.5 “Check code” for a BCC calculation.

Delimiter

CR (0Dh): End of packet

6.2. How to read the measurement value of the built-in temperature sensors.

MultiSync X461UN /X461HB /X431BT /P401 /P461 /P521 /P701 /S401 /S461 /S521 and MULTEOS M401 /M461

/M521 have three built-in temperature sensors.

The controller can monitor inside temperatures by using those sensors with external control.