Contents
2. Connectors and wiring
2.1 RS-232C Remote control
3.1 RS-232C Remote control
1. Application
4. Communication Format
4.1 Header block format fixed length
3rdbyte Destination Destination equipment ID. Receiver
4.2 Message block format
Header
Check code Delimiter
Message
4.5 Check code
Header Message
Check code
Delimiter
4.6 Delimiter
Header
Message
Check code
5.2 Get parameter reply
5. Message type
5.1 Get current Parameter from a monitor
5.3 Set parameter
5.4 Set parameter reply
5.5.2 Get Timing Report and Timing reply
5.5 Commands
5.5.1 Save Current Settings
5.5.3 NULL Message
6. Typical procedure example
6.1. How to change the “Brightness” setting
SOH-0-0-Monitor ID-D-1-2
Page
Step 1. Select a temperature sensor which you want to read
Delimiter CR 0Dh End of packet
7. Power control procedure
7.1 Power status read
7.2 Power control
1 The controller requests the monitor to control monitor power
8. Asset Data read and write
8.1 Asset Data Read Request and reply
8.2 Asset Data write
9. Date & Time read and write
9.1 Date & Time Read
1 The controller requests the monitor to write Date & Time
This command is used in order to write the setting of the Date & Time
9.2 Date & Time Write
Message STX 02h Start of Message
10.1 Schedule Read
This command is used in order to read the setting of the Schedule
10. Schedule read and write
0-830h, 38h Message length Message STX 02h Start of Message
0-130h,31h VGA 0-230h,32h RGB/HV 0-330h,33h DVI 0-530h,35h Video1
Page
10.2 Schedule Write
This command is used in order to write the setting of the Schedule
1 The controller requests the monitor to write Schedule
EX 0-130h, 31h Monday 0-430h, 34h Wednesday
2 The monitor replies a data for confirmation
Page
SOH-0-0-Monitor ID-B-0-C
STX-C-3-1-5-ST-PG-EN-ETX
1 The controller requests the monitor to write Schedule
bit 4 Friday bit 5 Saturday bit 6 Sunday EX 0-130h, 31h Monday
1-731h, 37h 23 =17h 1-831h, 38h Off timer isnt set
11.1 Self-diagnosis status read
This command is used in order to read the Self-diagnosis status
11. Self diagnosis
SOH 01h Start of Header 0 30h Reserved
This command is used in order to read a serial number
This command is used in order to read the Model Name
12. Serial No. & Model Name Read
12.1 Serial No. Read
13. Security Lock
13.1 Security Lock Control
SOH-0-MonitorID-0-A-1-0
STX-C-2-1-D-EN-P1-P2-P3-P4-ETX
P1 Security Pass code 1st 0-030h, 30h
P2 Security Pass code 2nd 0-030h, 30h
C-3-1-D 43h, 33h, 31h, 44h Security Lock Control reply command
ST-EN Lock condition result data ST Status 0-030h, 30h No error
0-130h, 31h Error
ETX 03h End of Message Check code BCC Block Check Code
Appendix
A. Operation Code OP code Table
ADJUST
AUDIO
SCHDULE
Page
OSD timer seconds
Menu tree reset
Information OSD
OSD Transparency
7 Autooffset
Option
Advanced
Terminate
Temperature sensor
Carbon footprint
50/50
All data are subject to change without notice
Revised at Mar.25/2010