NEC RS-232C user manual 3rdbyte Destination Destination equipment ID. Receiver

Models: RS-232C

1 50
Download 50 pages 13.24 Kb
Page 3
Image 3
3rdbyte) Destination: Destination equipment ID. (Receiver)

2ndbyte) Reserved: Reserved for future extensions. On this monitor, it must be ASCII '0'(30h).

3rdbyte) Destination: Destination equipment ID. (Receiver)

Specify a commands receiver’s address.

The controller sets the “MONITOR ID” or “GROUP ID” of the monitor controlled in here. On the reply, the monitor sets ‘0’ (30h), always.

“MONITOR ID”, “GROUP ID” to “Destination Address” conversion table is as follows,

Monitor

Destination

Monitor

Destination

Monitor

Destination

Monitor

Destination

ID

Address

ID

Address

ID

Address

ID

Address

1

41h(‘A’)

26

5Ah(‘Z’)

51

73h

76

8Ch

2

42h(‘B’)

27

5Bh

52

74h

77

8Dh

3

43h(‘C’)

28

5Ch

53

75h

78

8Eh

4

44h(‘D’)

29

5Dh

54

76h

79

8Fh

5

45h(‘E’)

30

5Eh

55

77h

80

90h

6

46h(‘F’)

31

5Fh

56

78h

81

91h

7

47h(‘G’)

32

60h

57

79h

82

92h

8

48h(‘H’)

33

61h

58

7Ah

83

93h

9

49h(‘I’)

34

62h

59

7Bh

84

94h

10

4Ah(‘J’)

35

63h

60

7Ch

85

95h

11

4Bh(‘K’)

36

64h

61

7Dh

86

96h

12

4Ch(‘L’)

37

65h

62

7Eh

87

97h

13

4Dh(‘M’)

38

66h

63

7Fh

88

98h

14

4Eh(‘N’)

39

67h

64

80h

89

99h

15

4Fh(‘O’)

40

68h

65

81h

90

9Ah

16

50h(‘P’)

41

69h

66

82h

91

9Bh

17

51h(‘Q’)

42

6Ah

67

83h

92

9Ch

18

52h(‘R’)

43

6Bh

68

84h

93

9Dh

19

53h(‘S’)

44

6Ch

69

85h

94

9Eh

20

54h(‘T’)

45

6Dh

70

86h

95

9Fh

21

55h(‘U’)

46

6Eh

71

87h

96

A0h

22

56h(‘V’)

47

6Fh

72

88h

97

A1h

23

57h(‘W’)

48

70h

73

89h

98

A2h

24

58h(‘X’)

49

71h

74

8Ah

99

A3h

25

59h(‘Y’)

50

72h

75

8Bh

100

A4h

ALL

2Ah(‘*’)

 

 

 

 

 

 

Group

Destination

ID

Address

A31h(‘1’)

B32h(‘2’)

C33h(‘3’)

Group

Destination

ID

Address

D34h(‘4’)

E35h(‘5’)

F36h(‘6’)

Group

Destination

ID

Address

G37h(‘7’)

H38h(‘8’)

I39h(‘9’)

Group

Destination

ID

Address

J

3Ah(‘:’)

 

 

Ex.) If you want to control a monitor that has the "ID No." as '1', specify a destination address

'A'(41h). If you want to control all of the monitors which are connected by a daisy chain, specify

a destination address ‘’(2Ah).

4thbyte) Source: Source equipment ID. (Sender)

Specify a sender address.

The controller must be ‘0’ (30h).

On the reply, the monitor sets the own MONITOR ID in here.

(3/50)

Page 3
Image 3
NEC RS-232C user manual 3rdbyte Destination Destination equipment ID. Receiver