Optima 45 - 3 | 6 |
APPLIANCE CERTIFICATION
This appliance is tested and safety approved under the following US and Canadian gas appliance standards:
-ANSI
-
Please contact Archgard Industries Ltd., if you have any questions regarding the certification of this appliance.
INSTALLATION CODES
This appliance must be installed by a qualified gas appliance installer. The installation must conform with the local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code,
SPECIFICATIONS
| Natural Gas (NG) | Propane (LP) |
Manifold Pressure | 1.6 - 3.5 in. W.C. (0.4 - 0.9 kPa) | 6.3 - 10.0 in. W.C. (1.6 - 2.5 kPa) |
|
|
|
Minimum Supply | 4.5 in. w.c. (1.2 kPa) | 11.0 in. w.c. (2.8 kPa) |
Pressure for Purpose of | ||
Input Adjustment |
|
|
Nominal Input Rating | 18,750 - 28,000 BTU/hr | 19,600 - 28,000 BTU/hr |
| (5.5 - 8.2 kW) | (5.7 - 8.2 kW) |
Orifice Size | #37 DMS (2.64 mm dia.) | #52 DMS (1.60 mm dia.) |
|
|
|
Altitude | 0 - 4500 ft (0 - 1372 M) | |
|
|
|
Primary Air Opening | 3/16” (5 mm) | 3/8” (9 mm) |
HIGH ALTITUDE INSTALLATION
When installing this appliance beyond 4500 ft. (1372 M) above sea level, the appliance must be properly