Optima 45 - 3 | 35 |
TROUBLESHOOTING Continued
SYMPTOM |
| ACTION |
The main burner does not | 3. Check to make sure the thermostat is set high enough to turn | |
turn on with the pilot lit. |
| on the appliance. |
Cont... | 4. Check that the remote switch or the thermostat is turned on. | |
| 5. | Check for weak pilot flame. If the flame is weak, check gas |
|
| supply, check pilot flame adjustment and check for blockage |
|
| of pilot orifice. |
| 6. | Check all connections to the valve for tight electrical contact. |
| 7. | Check for |
|
| and |
|
| the thermopile is defective. |
| 8. | Check for defective gas valve. |
|
| |
The main burner shuts off | 1. This may be the normal operation of a wall thermostat installed | |
when the appliance is |
| to appliances. |
warm. | 2. Check for good pilot flame on the thermopile. | |
| 3. | Check for good voltage from the thermopile. |
| 4. | Check for proper functioning of venting system (blocked ?). |
| 5. | Check wire connections. Expansion from heat affects a loose |
|
| connection. |
Sooty deposits on the glass | 1. If the flame is yellow and lazy, check for lint etc. around pri- | |
door. |
| mary air shutter. Increase primary air by opening the primary |
|
| air shutter if necessary. |
| 2. | Check for proper placement of the logs and branches. Ensure |
|
| logs and burner are clean. See that section in the instruction |
|
| manual. |
| 3. | Check for proper venting and blockage of the vent termination. |
| 4. | Check manifold pressure and clock input rating for |
Sharp blue flames with | 1. Too much primary air. Reduce primary air by closing the | |
flames lifting off the burner |
| primary air shutter. During cold temperatures, some flame |
at the ends. |
| lifting may occur during |
|
| |
Convection blower does not | 1. The convection fan is thermostatically controlled. It will only | |
turn on. |
| turn on when the appliance is |
|
| 15 minutes with the appliance on high. |
| 2. | Check for 120 VAC electrical supply to the appliance. |
| 3. | Check for proper mounting of the thermal snap disc. |
| 4. | Check electrical connections. |
| 5. | Check for defective thermal snap disc. |
| 6. | Check for defective convection blower speed controller. |
| 7. | Check for defective convection blower. |
|
|
|