FINAL INSTALLATION CHECK

Optima 45 - 3

30

FINAL INSTALLATION CHECK

Each Archgard Gas Fireplace is checked and tested at the factory prior to being packaged and shipped to our dealers and finally installed in your home. Archgard recommends that before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly, and that the electrical system is in working order. This will include:

1.Perform Leak tests of supply line, gas control valve, supply line from gas control valve and pilot assembly.

2.Clocking the appliance to ensure the correct firing rate (see rating plate or page 6 of this manual).

3.If required, adjusting the primary air to burner to ensure that the flame does not carbon or soot. (see rating plate or page 6 of this manual) .

4.Check for proper operation including correct drafting.

5.The FAN system should be turned ON for a minimum of 15 minutes to ensure the fan, rheo- stat and fan sensor are all working correctly. After the system has been checked, and con- firmed that the fan components are in working order, turn the fan system OFF and refer to the instructions for FIRST FIRE located in this manual.

As a reminder, a TAG is attached to all of our gas fireplaces. This TAG is located at the gas control valve. (See Fig 1).

Fig. 1

ARCHGARD INDUSTRIES LTD.

*** INSTALLER ***

IMPORTANT NOTICE

ALL GAS AND ELECTRICAL CONNECTIONS

**MUST ** BE CHECKED AND TESTED AT TIME OF INSTALLATION.

Any alteration to the product that causes carboning or sooting that results in any

damage or requires cleaning is not the responsibility of the manufacturer.

INITIAL OPERATION

1.Check that the appliance is properly vented and connected to the gas supply.

2.Check that the logs and branches are properly placed.

3.Check that all external parts, such as grills, door and faceplate are properly attached and fastened.

4.Do not operate this appliance with broken or cracked glass doors or without the door (s) in its correct (and latched) position. Do not use abuse the glass by either striking or slamming shut.

5.Check that there are no fingerprints left on gold surfaces or glass panels, as high temperatures can bake these prints permanently.