LOCATING GAS HEATER

Optima 45 - 3

10

LOCATING GAS HEATER

This appliance must be installed in a location that is free of plumbing, electrical wiring and heating or air conditioning ducts. Select a location that is accessible for venting.

See ALLOWABLE TERMINATION LOCATIONS listed in this manual.

NOTE: See venting chart for maximum and minimum vertical/horizontal venting configurations.

VENT TERMINATION LOCATIONS

1.See ALLOWABLE TERMINATION LOCATIONS and establish a suitable vent termination location.

2.In heavy snowfall areas make sure the vent termination is located where it can not be blocked by snow and from snowfall or snow removal equipment.

3.Locate the vent termination away from plants, bushes or any other object near the vent termination that will interfere or obstruct the air flow around it.

4.DO NOT recess vent termination into walls, sidings or planters.

5.Vent terminations located below 7ft (2.13 M) from grade level or anywhere that it can be a burn hazard to the public, such as patios and balconies, must be protected with an approved termination cage. If using Archgard Venting System order (Part # C-1).