µ
PD75P3116
22 Data Sheet U11369EJ3V0DS
Instruction Mnemonic Operand
No. of Machine
Operation
Addressing
Skip
Group
Bytes Cycle Area
Condition
Transfer MOV A, #n4 1 1 A n4 String-effect A
reg1, #n4 2 2 reg1 n4
XA, #n8 2 2 XA n8 String-effect A
HL, #n8 2 2 HL n8 String-effect B
rp2, #n8 2 2 rp2 n8
A, @HL 1 1 A (HL) *1
A, @HL+ 1 2+S A (HL), then L L+1 *1 L = 0
A, @HL– 1 2+S A (HL), then L L–1 *1 L = FH
A, @rpa1 1 1 A (rpa1) *2
XA, @HL 2 2 XA (HL) *1
@HL, A 1 1 (HL) A*1
@HL, XA 2 2 (HL) XA *1
A, mem 2 2 A (mem) *3
XA, mem 2 2 XA (mem) *3
mem, A 2 2 (mem) A*3
mem, XA 2 2 (mem) XA *3
A, reg 2 2 A reg
XA, rp’ 2 2 XA rp’
reg1, A 2 2 reg1 A
rp’1, XA 2 2 rp’1 XA
XCH A, @HL 1 1 A ←→ (HL) *1
A, @HL+ 1 2+S A ←→ (HL), then L L+1 *1 L = 0
A, @HL– 1 2+S A ←→ (HL), then L L–1 *1 L = FH
A, @rpa1 1 1 A ←→ (rpa1) *2
XA, @HL 2 2 XA ←→ (HL) *1
A, mem 2 2 A ←→ (mem) *3
XA, mem 2 2 XA ←→ (mem) *3
A, reg1 1 1 A ←→ reg1
XA, rp’ 2 2 XA ←→ rp’
Table MOVT XA, @PCDE 1 3 XA (PC13-8+DE)ROM
reference XA, @PCXA 1 3 XA (PC13-8+XA)ROM
XA, @BCDENote 1 3 XA (BCDE)ROM *6
XA, @BCXANote 1 3 XA (BCXA)ROM *6
Note Only the lower 3 bits in the B register are valid.