![](/images/new-backgrounds/1104977/10497767x1.webp)
Data Area for Output and Storage
Adjustment data have different reference data areas depending on each operation.
Adjustment Area
All Gain | : All adjustment data except Ref.Adjust data |
Ref. Adjust | : Ref.Adjust data |
Adjustment data fall into two: REF. ADJUST menu adjustment and the other adjustment data (Operate and Adjust menu). Data area falls into five:
Data Area |
|
INPUT LIST | : Registered data (100) areas corresponding to INPUT LIST |
DEFAULT DATA | : Default (6) areas divided by horizontal frequency. |
Cancel Data | : Data to be returned to default |
Ref.Adjust Data | : REF.ADJUST data (1) area |
Ref.Adjust (FACTORY AREA) | : REF.ADJUST data (1) area for factory preset. |
NOTE: See the
Output Data Area
| Ref.Adjust Data | All Gain |
Signal Select | Input List | Ref. Adjust Data |
|
|
|
Normalize | Default Data | Ref. Adjust Data (Factory Area) |
Load | Input List | Ref. Adjust Data |
Cancel | Cancel Data* | ← |
*The above list may be different if NORMAL/LOAD/CANCEL operation is performed during POINT convergence.
Output data during adjusting is the amount of data in each data area and data other than the current adjustment item ( data in working area).
Example for FINE adjustment
| Point Data while adjusting Fine |
|
|
Normalize | Default Data |
|
|
Load | Input List |
|
|
Cancel | Cancel Data + Point data except the current Fine data |
Storage Area of Data
STORE
All Gain | Ref. Adjust |
INPUT LIST | REF. ADJUST |
|
|
*Point adjustment has more than one item and each item has its own working area. However, there is only one area where data is saved with the Store function, which means no distinction is made among items in data.
34