Trap Setting

Address of the manager where the trap is to be sent.

 

Figure 32. Trap Setting

System Events:

Monitoring the system’s trap.

Device Bootup:

a trap when booting up the system.

Illegal Login:

a trap when there is using a wrong password login, and it will record

 

from where the IP to be login.

Twisted Pair Port Events:

Monitoring the twisted pair port status.

Abnormal* Receive Error:

a trap when there are receive data error in twisted pair port.

Abnormal* Transmit Error:

a trap when there are transmit data error in twisted pair port.

Abnormal*:

50 error packet count within 10 seconds.

PoE Events:

Monitoring the PoE ports status.

PoE Power fail:

A trap when the port’s power source fails or the PD64012 fails.

Power on/Power off:

A trap when the PoE port’s power is on and down.

Power over current:

A trap when the PoE port’s power is over current.

Power short circuit:

A trap when the PoE port’s power circuit was short.

Power threshold on/off:

A trap when the radio of the system power supply larger than or smaller

 

than the System power Threshold setting.

NP2500 24-Port 10/100 PoE + 2-Port 10/100/1000 WebSMART Switch User Guide

35

YML842 Rev1

 

Page 35
Image 35