New Buck Corporation 74 installation instructions Section Pre-Fabinsert Installation

Models: 74

1 37
Download 37 pages 52.32 Kb
Page 12
Image 12
SECTION III

SECTION III

PRE-FAB INSERT INSTALLATION

The Model 74 has been tested with the following UL listed manufactured Pre-Fab Fireplaces:

Heatilator Security

Tempco Preway

Marco FMI

Woodside Majestic

The Model 74 will fit any of the models that are large enough to accept them.

NOTE: A full chimney liner is required in a Zero Clearance or pre-fab fireplace.

NOTE: The ash lip, smoke baffle, and smoke shelf may be removed if necessary to provide room for these models. Any other alteration to the unit will void ALL NBC manufacturer's responsibility and liability. The warning label below must be attached to the back of the fire - place.

Except for the “NOTES” above, please follow the instructions for Masonry Insert Installation including Minimum Clearances for stove and floor protector in Section II.