Routine cleaning |
|
|
| Servicing instructions |
|
| |||
For routine cleaning, your machine is equipped with the | the following instructions must always be | ||||||||
observed |
|
|
|
| |||||
following accessories: |
|
|
| When cleaning and servicing the machine, replacing | |||||
| - Spraymaster, drive plate for pads, | ||||||||
| brown or green pad for | parts or when changing over to a different function, | |||||||
| drive plate for pads, red pad for High Speed |
| switch off the drive and remove the plug. | ||||||
Fill the spray can with the desired product. |
| The power supply lead must not be damaged by driving | |||||||
Fit the drive plate with the desired pad. |
| over it, crushing, tugging etc. |
|
| |||||
Start the machine. |
|
|
| Check the power supply lead regularly for signs of | |||||
When you pull the Spraymaster lever a few times the | damage. |
|
|
|
| ||||
| cleaning agent is sprayed onto the floor. Now start | The machine must not be used if the power supply lead | |||||||
| cleaning immediately until a shine is produced. | is not in perfect condition. |
|
| |||||
We advise cleaning the surface in relatively small areas | When using or replacing the power supply or | ||||||||
| at a time. The machine is ideal for cleaning with | equipment supply leads, use only those specified by | |||||||
| polymer dispersions. The coatingʼs resistance to | the manufacturer. |
|
|
| ||||
| foot traffic and general wear and tear is preserved. | When replacing the | |||||||
| Streaks and marks are easier to remove. |
| power supply or equipment supply leads, splash | ||||||
|
|
|
|
| protection and mechanical strength must be | ||||
Polishing |
|
|
| assured. |
|
|
|
| |
|
|
| When transporting the machine in lifts, put the shaft/ | ||||||
|
|
|
|
| bar in a vertical position so that it cannot catch on | ||||
For polishing, equip your machine with the following | the lift walls. |
|
|
| |||||
accessories: |
|
|
| The shaft/bar is automatically secured against recoil by | |||||
| - Drive plate for pads, white pad. |
|
| the patented shaft/bar adjustment unit. | |||||
Fit the drive plate with the pad. |
|
| Only the spray and cleaning agents suitable for the | ||||||
Then start the machine. |
|
|
| machineʼs purpose may be used. |
|
| |||
|
|
| Never use highly flammable, combustible, toxic, health- | ||||||
Service |
|
|
| hazardous, corrosive or irritant substances. | |||||
|
|
|
|
| Repairs, including the fitting of spray agent lines | ||||
For repairs, please contact your specialist wholesaler or | and hoses, may only be carried out by approved | ||||||||
| one of the service shops. |
|
| customer service shops or by specialists in this | |||||
You will be expertly and quickly served. |
| field who are familiar with all the relevant safety | |||||||
Warning! This machine is only intended for use on | regulations. |
|
|
| |||||
Storage |
|
|
|
| |||||
| level surfaces with a maximum gradient of up to 2 %. |
|
|
|
| ||||
Warning! This machine is not approved for use on | When the machine is not being used, store it in a dry | ||||||||
| public paths and roads. |
|
|
| |||||
|
|
|
|
| place and in normal room conditions (not below under | ||||
|
|
|
|
| 0°C). |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Technical specifications |
|
|
|
|
|
|
|
|
|
| SD | SD | SDM | SDM | SDM | SDM | SDM |
|
| A.C. motor | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 |
|
| Rated power | 1000 | 1100 | 1200 | 1500 | 1800 | 1800 |
| |
|
| 5,6 | 5,7 | 5,2 | 6,5 | 5,2/8,1 | 7,2 | 7,2 |
|
| Brush (rpm) | 165 | 400 | 180 | 450 | 190/380 | 900/1500 | 1500 |
|
| Brush (mm) | 430 | 430 | 430 | 430 | 430 | 430 | 530 |
|
| Working height (mm) | 250 | 250 | 330 | 330 | 330 | 130/320 | 130/320 |
|
| Working weight (kg) | 30 | 31 | 36 | 40 | 40 | 44 | 46 |
|
| Protection class | I/IPx4 | I/IPx0 | I/IPx4 | I/IPx0 | I/IPx4 | I/IPx0 | I/IPx0 |
|
| X | X | X | X | X | X | X |
| |
| Handle vibration level m/s2 | 1,05 | 1,05 | 1,05 | 1,05 | 1,05 | 1,05 | 1,05 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9