Electrical components

 

 

Values

 

 

 

 

 

 

Electrical system voltage

 

 

24 V

 

 

 

 

Vacuum system motor

 

 

310 W, 3,000 rpm

 

 

 

 

Main broom motor

 

 

500 W, 550 rpm

 

 

 

 

Drive system motor

 

 

750 W, 315 rpm

 

 

 

 

Side broom reduction unit

 

 

90 W, 85 rpm

 

 

 

 

Filter shaker motor

 

 

90 W, 5,700 rpm

Closed pocket filter shaker motor (optional)

 

110 W, 3,000 rpm

Batteries

 

 

Values

 

 

 

 

 

Standard WET batteries with acid electrolyte, in serial connection

 

Four 6 V 180 Ah batteries

 

 

 

Optional WET battery with acid electrolyte

 

One 24 V 240 Ah battery

 

 

 

Optional WET or GEL batteries, available at any Nilfisk Alto Retailer

 

Total voltage 24 V

 

 

 

 

Battery maximum capacity

 

 

330 Ah

Battery case size (length x width x height)

 

800 x 300 x 150 mm

Battery compartment maximum size (width x length x height)

 

800 x 360 x 380 mm

Dust vacuuming and filtering

 

 

Values

 

 

 

 

 

 

Paper dust filter 15-20 μm

 

 

3.6 m2

 

 

 

Main broom compartment vacuum

 

10.9 mm/H2O

Hopper hydraulic lifting system

 

Values

 

 

 

 

 

Pump

 

 

Parker 108 AE S32 - 24 V

 

 

 

 

Maximum pressure

 

 

110 Bar

 

 

 

 

Oil tank capacity

 

 

0.75 litres

 

 

 

 

Hydraulic circuit total capacity

 

 

1.4 litres

 

 

 

Hydraulic system oil (at ambient temperature above 10°C)

 

AGIP Arnica 46 (*)

 

 

 

 

CAUTION!

If the machine is to be used at ambient temperatures below +10°C, the oil should be changed with equivalent oil having a viscosity of 32 cSt. For temperatures below 0°C, use an oil with lower viscosity.

(*)See the oil technical data and reference data tables below.

TECHNICAL DATA

AGIP ARNICA

 

46

32

Viscosity at 40°C

mm2/s

45

32

 

 

 

 

Viscosity at 100°C

mm2/s

7.97

6.40

 

 

 

 

Viscosity index

/

150

157

 

 

 

 

Flash point COC

°C

215

202

 

 

 

 

Pour point

°C

-36

-36

 

 

 

 

Density at 15°C

kg/l

0.87

0.865

 

 

 

 

REFERENCE DATA

ISO-L-HV

ISO 11158

AFNOR NF E 48603 HV

AISE 127

ATOS Tab. P 002-0/I

BS 4231 HSE

CETOP RP 91 H HV

COMMERCIAL HYDRAULICS

Danieli Standard 0.000.001 (AGIP ARNICA 22, 46, 68)

EATON VICKERS I-286-S3

EATON VICKERS M-2950

DIN 51524 t.3 HVLP

LAMB LANDIS-CINCINNATI P68, P69, P70

LINDE

PARKER HANNIFIN (DENISON) HF-0

REXROTH RE 90220-1/11.02

SAUER-DANFOSS 520L0463

10

FLOORTEC R 680 B

1463516000(1)2008-05 A

Page 72
Image 72
Nilfisk-ALTO R 680 B Electrical components Values, Batteries Values, Hopper hydraulic lifting system Values