ENGLISH | USER MANUAL |
|
|
|
| ||
|
|
|
|
|
|
|
|
Electrical components |
|
| Values |
|
| ||
|
|
|
|
Electrical system voltage |
|
| 24 V |
|
|
|
|
Vacuum system motor |
|
| 310 W, 3,000 rpm |
|
|
|
|
Main broom motor |
|
| 500 W, 550 rpm |
|
|
|
|
Drive system motor |
|
| 750 W, 315 rpm |
|
|
|
|
Side broom reduction unit |
|
| 90 W, 85 rpm |
|
|
|
|
Filter shaker motor |
|
| 90 W, 5,700 rpm |
Closed pocket filter shaker motor (optional) |
| 110 W, 3,000 rpm | |
Batteries |
|
| Values |
|
| ||
|
|
| |
Standard WET batteries with acid electrolyte, in serial connection |
| Four 6 V 180 Ah batteries | |
|
|
| |
Optional WET battery with acid electrolyte |
| One 24 V 240 Ah battery | |
|
|
| |
Optional WET or GEL batteries, available at any Nilfisk Alto Retailer |
| Total voltage 24 V | |
|
|
|
|
Battery maximum capacity |
|
| 330 Ah |
Battery case size (length x width x height) |
| 800 x 300 x 150 mm | |
Battery compartment maximum size (width x length x height) |
| 800 x 360 x 380 mm | |
Dust vacuuming and filtering |
|
| Values |
|
| ||
|
|
|
|
Paper dust filter |
|
| 3.6 m2 |
|
|
| |
Main broom compartment vacuum |
| 10.9 mm/H2O | |
Hopper hydraulic lifting system |
| Values | |
| |||
|
|
|
|
Pump |
|
| Parker 108 AE S32 - 24 V |
|
|
|
|
Maximum pressure |
|
| 110 Bar |
|
|
|
|
Oil tank capacity |
|
| 0.75 litres |
|
|
|
|
Hydraulic circuit total capacity |
|
| 1.4 litres |
|
|
| |
Hydraulic system oil (at ambient temperature above 10°C) |
| AGIP Arnica 46 (*) | |
|
|
|
|
CAUTION!
If the machine is to be used at ambient temperatures below +10°C, the oil should be changed with equivalent oil having a viscosity of 32 cSt. For temperatures below 0°C, use an oil with lower viscosity.
(*)See the oil technical data and reference data tables below.
TECHNICAL DATA
AGIP ARNICA |
| 46 | 32 |
Viscosity at 40°C | mm2/s | 45 | 32 |
|
|
|
|
Viscosity at 100°C | mm2/s | 7.97 | 6.40 |
|
|
|
|
Viscosity index | / | 150 | 157 |
|
|
|
|
Flash point COC | °C | 215 | 202 |
|
|
|
|
Pour point | °C | ||
|
|
|
|
Density at 15°C | kg/l | 0.87 | 0.865 |
|
|
|
|
REFERENCE DATA
ISO 11158
AFNOR NF E 48603 HV
AISE 127
ATOS Tab. P
BS 4231 HSE
CETOP RP 91 H HV
COMMERCIAL HYDRAULICS
Danieli Standard 0.000.001 (AGIP ARNICA 22, 46, 68)
EATON VICKERS
EATON VICKERS
DIN 51524 t.3 HVLP
LAMB
LINDE
PARKER HANNIFIN (DENISON)
REXROTH RE
10