ENGLISH | USER MANUAL | |
|
| |
|
|
PANEL DUST FILTER CLEANING AND INTEGRITY CHECK
NOTE
Besides the standard paper filter, polyester filters are also available. The following procedure is applicable to each type of filter.
9.Drive the machine on a level ground and engage the parking brake with the pedal (75) and the lever (68).
10.Turn the ignition key (67) to “0”.
11.Open the hood (22) and fasten it with the support rod (36).
12.Disconnect the battery connector (25).
13.Disconnect the vacuum system motor connector (30).
14.Release the fasteners (A, Fig. 12) and remove the vacuum system cover (B).
15.Disconnect the connector (A, Fig. 13) from the filter shaker.
16.Unscrew the knobs (B, Fig. 13) and remove the filter mounting frame (C).
17.Remove the dust filter (D, Fig. 13).
18.In an outdoor area, clean the filter by shaking it on a level and clean surface, tapping the side (A, Fig. 14) opposite to the wire gauze (B).
Complete the cleaning procedure by using compressed air (C) at maximum 6 Bar, blowing only from the side protected by the wire gauze (B), at a minimum distance of 30 cm.
Check the filter body for tears.
According to the filter type, observe the following cautions:
•Paper filter (standard): Do not use water or detergents to clean it, otherwise it can be damaged.
•Polyester filter (optional): For a better cleaning, it is allowed to wash the filter with water and
19.If necessary, clean the filter compartment rubber gasket (A, Fig. 15) along its perimeter and check it for integrity. If necessary, replace it.
20.Assemble the components in the reverse order of disassembly, and note the following:
•Install the filter with the wire gauze (B, Fig. 14) facing upwards.
A
A | B | A |
|
| Figure 12 | P100225 | P100226 |
|
| Figure 13 |
P100227 | P100228 |
Figure 14 | Figure 15 |
24
FLOORTEC R 680 B |