4.SYMPTOM: THE WALKING BELT IS OFF-CENTER

a. If the walking belt has shifted to the left: Remove the

key and unplug the power cord.Using the included allen

wrench, turn the roller adjustment bolts in the directions shown, 1/4 of a turn each. Be careful not to overtighten the walking belt. Plug in the power cord, insert the key and use the treadmill for a few minutes. Repeat until the walk- ing belt is centered.

b.If the walking belt has shifted to the right: Remove the

key and unplug the power cord.Using the included allen

wrench, turn the roller adjustment bolts in the directions shown, 1/4 of a turn each. Be careful not to overtighten the walking belt. Plug in the power cord, insert the key and use the treadmill for a few minutes. Repeat until the walk- ing belt is centered.

a

b

c.If the walking belt slips when walked on: Remove the

key and unplug the power cord.Using the included allen

wrench, turn both roller adjustment bolts clockwise 1/4 of a turn. When the walking belt is properly tightened, you should be able to lift each side of the walking belt 1 to 2 inches off the walking platform. The center of the walking belt should just touch the walking platform. Make sure to keep the walking belt centered. Plug in the power cord, in- sert the key and run the treadmill for a few minutes.

Repeat until the walking belt is properly tightened.

5.SYMPTOM: THE WALKING BELT STOPS OR THE INCLINE CANNOT BE ADJUSTED EVEN THOUGH THE CONSOLE REMAINS LIT

c

a. This indicates that a controller error may have occurred. To correct the problem, refer to step 8 on page 23.