Nortel Networks NN43001-318 manual Step Action

Models: NN43001-318

1 108
Download 108 pages 20.36 Kb
Page 29
Image 29

Installing ISDN BRI hardware for line applications 29

Each SILC provides eight four-wire full-duplex ports. These ports are connected to building wiring to form DSLs. These ports are polarity-sensitive. Signal polarity must be maintained along each loop.

Each UILC provides eight two-wire full-duplex ports. These ports are connected to twisted pair building wiring to form DSLs. These DSLs are not polarity-sensitive and, although recommended, it is not necessary to maintain signal polarity along each loop.

Procedure 9

Cross-connecting SILC and/or UILC ports to the building wiring

Step Action

Perform the following steps to cross-connect the SILC and/or UILC ports to the building wiring.

1Identify the card type (SILC or UILC) for a connector on the MDF. Refer to the IPE or CE module card location form at the end of this chapter, which shows the card type connected to each I/O panel connector.

2Identify transmit and receive pairs on the top of the labeled distribution strip for the card type and module type you are connecting. To identify SILC or UILC ports and their pin numbers, refer to Table 5 "NT8D37 IPE moduleSILC and UILC pair-terminations for connectors A, E, K, R (12-cable configuration)" (page 33) through Table 11 "Card location form: NT8D37 IPE module (12-cable configuration)" (page 44), which begins on Table 5 "NT8D37 IPE moduleSILC and UILC pair-terminations for connectors A, E, K, R (12-cable configuration)" (page 33).

Note: In Table 5 "NT8D37 IPE moduleSILC and UILC pair-terminations for connectors A, E, K, R (12-cable configuration)" (page 33) through Table 11 "Card location form: NT8D37 IPE module (12-cable configuration)" (page 44), the cable pair designated T- T+ is the transmit pair and the pair designated R+ R- is the receive pair of the S/T interface. The cable pair designated T R is the Tx and Rx of the 2B1Q full-duplex U interface.

3Identify building wires connected to the bottom of the distribution strip. Refer to the Building Cable Plan, which identifies wires between distribution frames and wall outlets. The Building Cable Plan is developed according to instructions in the "Planning the Site" section in Communication Server 1000M and Meridian 1 : Large System Planning and Engineering (553-3021-120).

4Plug in the terminating resistor at the appropriate location in each S/T DSL. See "Engineering Guidelines" in the ISDN Basic Rate

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318 01.02 Standard

Release 5.0 20 June 2007

Copyright © 2003-2007, Nortel Networks

Page 29
Image 29
Nortel Networks NN43001-318 manual Step Action

NN43001-318 specifications

Nortel Networks NN43001-318 is a sophisticated telecommunications component that plays a pivotal role in networking technologies. Designed for high-performance networking environments, this modular circuit pack is part of Nortel's long-standing reputation for reliability and efficiency in communication systems.

One of the standout features of the NN43001-318 is its support for advanced digital processing capabilities, which allows for the seamless transmission of data across various network formats. This circuit pack serves as a bridge between legacy systems and modern digital infrastructures, facilitating smooth upgrades and integration. Its versatility makes it suitable for a range of networking applications, from small businesses to large enterprises.

The NN43001-318 is equipped with multiple interfaces, allowing it to connect with various types of network equipment effortlessly. This characteristic is particularly advantageous for organizations looking to expand their network capabilities without a complete overhaul. The modular nature of the component ensures that it can be easily replaced or upgraded, thus prolonging the lifespan of overall network systems.

In terms of technological advancements, the NN43001-318 leverages multiple protocols to ensure reliable communications across diverse platforms. It supports Voice over IP (VoIP) technologies, which enhances the quality of voice communications while reducing costs associated with traditional telephony. Additionally, the circuit pack is designed to minimize latency, making it ideal for real-time applications where speed and efficiency are critical.

Security is another integral aspect of the NN43001-318, supporting encryption protocols to secure data transmission. This is essential in today's environment, where cybersecurity concerns are paramount. The combination of advanced encryption and robust processing power ensures that sensitive information remains protected, giving organizations peace of mind.

Moreover, the NN43001-318 aids in improving network management through its built-in diagnostic capabilities. These features allow network administrators to monitor performance and troubleshoot potential issues proactively, enhancing overall service quality.

In summary, Nortel Networks NN43001-318 is a versatile and powerful circuit pack that embodies the cutting-edge technologies required for modern networking. Its ability to support various protocols, combined with secure communications and efficient management features, makes it a valuable asset for any organization looking to enhance its networking infrastructure.