Nortel Networks NN43001-318 manual Installation procedures, Summary, Cabinet Systems

Models: NN43001-318

1 108
Download 108 pages 20.36 Kb
Page 56
Image 56

56Configuring ISDN BRI hardware

Configure DSL for ISDN BRI trunking in LD 27. Refer to Table 14 "Correct responses to LOOP and MISP prompts in LD 27" (page 56) for the correct response to the MISP prompt.

Table 14

Correct responses to LOOP and MISP prompts in LD 27

 

 

LOOP

MISP

 

 

 

 

 

 

 

Main

1

– 9

1

– 9

 

 

 

 

 

 

 

Expansion 1

11

– 19

11

– 19

 

 

 

 

 

 

Cabinet Systems

Expansion 2

21

– 29

21

– 29

 

 

 

 

 

 

 

Expansion 3

31

– 39

31

– 39

 

 

 

 

 

 

 

Expansion 4

41

– 49

41

– 49

 

 

 

 

 

 

 

MG 1000S 1

11

– 14

11

– 14

 

 

 

 

 

 

CS 1000S and Chassis

MG 1000S 2

21

– 24

21

– 24

Systems

MG 1000S 3

31

– 34

31

– 34

 

 

 

 

 

 

 

MG 1000S 4

41

– 44

41

– 44

 

 

 

 

 

 

Installation procedures

Summary

The following is a summary of the procedures to install and configure ISDN BRI hardware. Collectively, the procedures apply to line, packet data, and trunking applications. Individually, some procedures apply only to line, packet data, or trunking.

Before beginning the procedures, ensure the system is installed and operational. Perform the procedures in the order shown.

Step Action

1Select the card slots. See Procedure 14 "Selecting the card slots" (page 58).

2Remove the MISP, if previously installed. See Procedure 16 "Removing the MISP" (page 60).

3Install the clock controller on the MISP (for trunking applications only). "Installing the clock controller on the MISP (for trunking applications)" (page 60)

4Install the MISP. See Procedure 15 "Installing the MISP" (page 59).

Note 1: A clock controller is only required for ISDN BRI trunk applications. The system supports a single active clock controller (CC). This clock controller can support both a primary and a

Nortel Communication Server 1000

ISDN Basic Rate Interface Installation and Commissioning

NN43001-318 01.02 Standard

Release 5.0 20 June 2007

Copyright © 2003-2007, Nortel Networks

Page 56
Image 56
Nortel Networks NN43001-318 manual Installation procedures, Summary, Correct responses to Loop and Misp prompts in LD