16Chapter 1 Uninterruptable Power Supply (UPS) Overview

The UPS device is supported in all markets (110~120V and 220~240V power standards). All BCMs using version 3.5 software or higher can use the UPS device.

BCM and UPS power and control connections

The UPS device operates in parallel with the BCM 200, 400, and 1000. The BCM obtains power through the UPS. The UPS obtains power from a conventional AC power source.

The UPS meets BCM power delivery requirements for 110~120 and 220~240 Volt standards. The BCM operational power usage range (shown in the following table) is compatible with the UPS operating range.

BCM Input Power Source

110 ~ 120

Volt power standards

220 ~ 240

Volt power standards

 

 

 

 

 

 

Minimum (VAC)

 

Maximum (VAC)

Minimum (VAC)

 

Maximum (VAC)

 

 

 

 

 

 

90.0

 

130.0

220.0

 

265.0

 

 

 

 

 

 

The serial connection between the BCM and UPS provides power monitoring and control capability. The UPS service uses standard RS232 serial protocol. Figure 2 shows the physical BCM connections and OAM topology.

Figure 2 UPS/BCM power connections and topology

 

Unified Manager

Local Area

Workstation provides UPS

Network

configuration, service

 

activation and OAM

 

monitoring applications

CTM 4

 

1 Aux 2

34

 

UPS device

 

 

 

 

 

 

 

DSM 16+

Plug BCM power

Plug UPS into AC

 

 

 

 

 

 

 

 

1

2

3

4

1

2

3

4

cord into UPS

power source

 

 

 

 

 

 

 

 

Pow erS tat us

 

 

 

 

 

 

 

 

COM port supports a DB9 serial connection to a UPS for power monitoring

P0607274 02