Monitor the Uninterruptable Power Supply

This section describes how to monitor the Uninterruptable Power Supply (UPS) on the Business Communications Manager (BCM) 200, 400, and 1000 models.

This section describes the following procedures:

Access the UPS Status monitor on page 28

Access the UPS OM and log reports on page 29

Access the UPS status report on page 30

Test the UPS on page 31

Monitor the UPS

The Business Communications Manager UPS service communicates with the UPS device through a serial (DB9) cable. The UPS service provides the following capabilities:

Monitors the UPS using the COM port. The BCM polls the UPS device every 60 seconds.

Power source failure notification is sent to the OAM and alarm subsystem and to the recovery application.

Provides a warning signal when UPS battery power is low.

Allows you to perform a remote UPS shutdown.

Allows an auto power off for the Business Communications Manager.

There are two methods to monitor the UPS:

1Select the UPS Status monitor tab to monitor the UPS device only (see “Access the UPS Status monitor” on page 28)

2Select the UPS Status report to monitor the UPS device and BCM UPS service (see “Access the UPS Status monitor” on page 28).