Chapter 2 Install and Initialize the Uninterruptable Power Supply 25

After 15 minutes, the service switches back to the UPS to enable the UPS (if the UPS was originally selected and enabled).

To extend the Console time, stop the UPSConsoleToggle using the command “Net Stop UPSConsoleToggle”.

The UPS service needs to be enabled from the Unified Manager when the user ends the console session.

Enable UPSConsoleToggle

Use this procedure to enable the UPSConsoleToggle service.

1Wait for all services to be up and running.

2Verify that the UPS service is running.

3If UPS service is running, change its start-up type to Manual-Start and the console CMDRMT service to Auto-Start, then stop UPS service and start Console service.

4Wait for 15 minutes.

5Toggle the UPS/Console.

6Change the console start-up type to Manual-Startand the UPS to Auto-Start. This stops the console service and starts the UPS service.

7Stop the UPSConsoleToggle service.

8This procedure is complete.

UPS Installation and Configuration Guide

Page 25
Image 25