18Chapter 1 Uninterruptable Power Supply (UPS) Overview

Operating conditions: send a message when internal UPS operating temperature falls outside of the upper or lower threshold.

Refer to the following table for further information on event messages.

Table 1 UPS Event messages

Event ID

Event

Type

 

 

 

1005

Administrative shutdown

Info

 

 

 

100500

Administrative shutdown started

Info

 

 

 

100501

Administrative shutdown: User

Info

 

initiated

 

 

 

 

100502

Administrative shutdown: Weekly

Info

 

shutdown

 

 

 

 

100503

Administrative shutdown: Daily

Info

 

shutdown

 

 

 

 

110000

Ambient temperature back within

Info

 

thresholds

 

 

 

 

110100

Ambient humidity back within

Info

 

thresholds

 

 

 

 

301400

Base module fan needs repair

Error

 

 

 

301500

Base module bypass power supply

Error

 

needs repair

 

 

 

 

310001

Below lower ambient temperature

Warn

 

threshold

 

 

 

 

310101

Below humidity threshold

Warn

 

 

 

2037

Bypass contactor failed

Error

 

 

 

1040

Bypass contactor OK

Info

 

 

 

1033

Battery added

Info

 

 

 

1034

Battery removed

Info

 

 

 

301000

Check installation of Smart Cell

Warn

 

signal cable

 

 

 

 

310002

Exceeded upper ambient

Warn

 

temperature threshold

 

 

 

 

310102

Exceeded upper humidity threshold

Warn

 

 

 

203800

Input circuit breaker tripped

Info

 

 

 

203900

Input circuit breaker reset

Info

 

 

 

200301

Low battery condition

Warn

 

 

 

103500

Main Intelligence module OK

Info

 

 

 

103600

Main Intelligence module added

Info

 

 

 

Event ID

Event

Type

 

 

 

1002

Communication Established

Info

 

 

 

300400

Communication lost while on

Info

 

battery

 

 

 

 

300000

Unable to communicate with UPS

Warn

 

 

 

300200

UPS self-test failed

Error

 

 

 

100700

UPS returned from low battery

Info

 

condition

 

 

 

 

100900

UPS batteries no longer need

Info

 

replacing

 

 

 

 

101300

UPS overload condition solved

Info

 

 

 

101400

UPS runtime calibration initiated

Info

 

 

 

101500

UPS runtime calibration completed

Info

 

 

 

1004

UPS self-test passed

Info

 

 

 

101700

UPS returned from bypass

Info

 

 

 

1102

UPS internal temperature in

Info

 

bounds

 

 

 

 

200000

UPS on battery

Info

 

 

 

200001

UPS on battery: High input line

Warn

 

voltage

 

 

 

 

200002

UPS on battery: Brownout

Warn

 

 

 

200003

UPS on battery: Blackout

Warn

 

 

 

200004

UPS on battery: Small momentary

Warn

 

sag

 

 

 

 

200006

UPS on battery: Deep momentary

Warn

 

sag

 

 

 

 

200005

UPS on battery: Small momentary

Warn

 

spike

 

 

 

 

200008

UPS on battery: Simulated power

Warn

 

failure

 

 

 

 

103100

UPS module added

Info

 

 

 

103200

UPS module removed

Info

 

 

 

200200

UPS enabling SmartBoost

Info

 

 

 

P0607274 02

Page 18
Image 18
Nortel Networks P0607274 0 manual UPS Event messages