24Chapter 2 Install and Initialize the Uninterruptable Power Supply

5Select the UPS Configuration tab from the UPS setup screen. The UPS Configuration screen appears (see Figure 3 on page 24).

Figure 3 UPS Configuration screen

6Select the UPS radio button to enable the serial port for use by the UPS.

7Select the power source type (110 ~ 120v or 220 ~ 240v).

Note: Once the UPS is selected and enabled on the Unified Manager “Serial Selection Page”, the UPS sends the message “UPS Communication Established” to the NT event log, when the UPS communication started. If the BCM loses or cannot establish a link to the UPS, an error log appears “Unable to Communicate with the UPS”.

8This procedure is complete.

UPSConsoleToggle Service

UPSConsoleToggle is an Auto-Start service that initiates at system boot time to enable the serial console for 15 minutes. Plug the console serial cable into the BCM and work on BCM console for a period of 15 minutes.

P0607274 02

Page 24
Image 24
Nortel Networks P0607274 0 manual UPSConsoleToggle Service, UPS Configuration screen