Industry Sector, IA&DT

Configuring manual mode for the drain valve of the reservoir

We configure an additional button for opening the drain valve.

From the Tools window, under Elements, drag a button to the root screen.

Under General, for Text OFF, enter "drain open". Select the Text ON check box and enter the text "drain open".

Caution! Do not press the Enter key after entering the text; otherwise, a new line will be created.

Set the position and the size.

Under Press, select the function “SetBitWhileKeyPressed” in the function list.

Select “manual_drain_reservoir” as tag from DB1.

SCE Training Curriculum

Page 84 of 118

To be used only at Educational and R&D Facilities

TIA Portal Module 090-010, Edition 03/2013

 

Unrestricted / © Siemens AG 2013. All Rights Reserved

SCE_EN_090-010_R1209_ WinCC Advanced with Runtime and TP700 Comfort Panel