Industry Sector, IA&DT
SCE Training Curriculum Page 115 of 118 To be used only at Educational and R&D Facilities
TIA Portal Module 090-010, Edition 03/2013 Unrestricted / © Siemens AG 2013. All Rights Reserved
SCE_EN_090-010_R1209_ WinCC Advanced with Runtime and TP700 Comfort Panel
Create an adjuster with the name "SCHMIDT" and the password "KLAUS".
Create a developer with the name "HUBER" and the password "FRANZ".

13.3 Assigning authorizations

Only users with operator control authorization are permitted to operate the start button and select a color
mixture from the recipes.
Only adjusters are authorized to switch the operating mode to manual operation of the plant.
Only developers are permitted to change or enter new recipe data records.
No access protection is required for all other functions, such as screen changes.

Start button security

Open the root screen and select the "START" button.
Under Security, select the "Operator control" authorization.
Set the check mark for Allow operator control.