Installation
Ultra Wide SCSI Mode 23
2Connect the other end of the data cable to the Channel #0 SCSI connector on
the right side or upper I/O Interface card.
3If required, connect one end of the second one meter data cable to the
Channel #2 connector on the AM RAID Controller.
4Connect the other end of the second data cable to the Channel #1 SCSI
connector on the right side or upper I/O Interface card.
NOTE: SCSI termination is automatic and requires no user configuration. Refer
to “Termination” on page 21 for information on systems using DEC
Fault bus protocol.
5Turn on the power to the CR8e. After the power-on self-test has completed,
Status and Channel Mode LEDs will be solid green.
6Access the Options menu on the Operator Control Panel and choose the
SAFTE CHAIN ID selection. Choose the “None” selection, refer to “SAFTE
CHAIN ID” on page 50.
7After setting the cabinet identifications you must power cycle the subsystem.
Observe normal power cycling precautions by waiting a minimum of five (5)
seconds before adding power again.
This will reset the SCSI IDs to a default setting that prevents a SCSI ID
conflict under normal conditions.
8Power up your computer system and run the configuration program.
This completes the hardware installation.
Rear View CR8e
with Dual-Bus Module installed.
TOP
I/O Interface
Card
1 meter data cable
1 meter data cable
I/O Interface
Card
Ultra SCSI
RAID Controller
Ch 0 Ch 1
Ch 0 Ch 1
Ch 1
Ch 2