MUTE input, however, will always override other volume response values with the “XM” response.

*********************************************************************************

COMMAND:

*ZxxSETSR<CR> ZoneSet STATUS REQUEST where xx is zone # from 1 to 12.

RESPONSE:

#ZxxORp,BASSyy,TREByy,GRPq,VRSTu

-p = 1 if at least one of the permanent

 

 

values have been overridden* by an RS232 command.

 

 

-yy = EQ level, dB, 12 to +0 (flat) to

+12 in 2 dB increments if set by RS232, -8, -6,-4, 0, +4, +6, +8 if set on keypad.

-q = 0 if SOURCE GROUP is ON 1 if SOURCE GROUP is OFF

-u = 0 if VOLUME RESET is ON 1 if VOLUME RESET is OFF

*override set to 1 FOR THIS ZONE only if one of commands *ZxxBASSyy<CR>, *ZxxTREByy<CR>, or *ZxxGRPq<CR> are issued (see descriptions below).

Once a parameter has been SET by one of these commands, it will remain UNTIL:

a. power is cycled on the Main Unit either with the front panel power switch or by removing AC power. Upon power-up, the system will restore keypad permanent

settings (see the User Manual for details on how to perform these settings).

b. an operator manually sets one of these parameters from a keypad. This takes the unit out of OVERRIDE state, but

other RS232-commanded settings will remain until another RS232 command overrides them, or power is cycled.

This response is also issued whenever these parameters are set from a keypad.

*********************************************************************************

COMMAND: *ZxxON<CR> Turn zone xx ON.

RESPONSE: Same response as for *ZxxCONSR<CR>

*********************************************************************************

COMMAND: *ZxxOFF<CR> Turn zone xx OFF.

RESPONSE: Same response as for *ZxxCONSR<CR>

*********************************************************************************

COMMAND: *ALLOFF<CR> Turn ALL zones OFF.

RESPONSE: #ALLOFF<CR>

This RESPONSE is also issued when ALL OFF is pressed on any KEYPAD.

*********************************************************************************

COMMAND: *ALLV+<CR> Ramp ALL zones UP at a 10 dB/second rate in 1 dB steps.

RESPONSE: #ALLV+<CR>

The ramp action will be cancelled when all zones reach MAXIMUM volume, or when an *ALLHLD<CR> Command is received. Note that to stop the ramp with this command before maximum volume, one reference zone must be periodically polled with a